Water Tower
Condition:New | Cooling Type:Counter Flow | Material:FRP | Place of Origin:Zhejiang China (Mainland) |
Brand Name:SHUANG FENG | Model Number:SF-xxT | Voltage:220V~415V | Power(W):1.0Kw-5.5Kw |
Dimension(L*W*H):According to the Cooling tower models | Weight:According to the Cooling tower models | Certification:CE | Warranty:12 months |
After-sales Service Provided:No overseas service provided | Cooling tower fill sheet:PVC | Cooling tower shell material:FRP |
SHUANGFENG SF-xxT series FRP Cooling tower
1) Good shape with small outside size, light weight
2) Optimum structure
3) The cooling tower body is made of FRP, which is anti-aging, anti-corrosion, without fading and distortion.
4) Noise: The lowest noise blower and unique noise elimination technology is adopted to reduce the noise to a minimum level
5) With reliable operation: All steel structure brackets are galvanized and corrosion resistant. The usage life is twice longer compared with similar products
6) Simple operation and maintenance: CTNC intelligent control system is adopted to realize labor free management
7) The angles of all the fans are regulative and axial-flow, which are made of advanced engineering plastics.
8) All the motors are sealed, which can be used in the severe weather and circumstances.
9) The casing and water plate of the cooling tower are made of fiberglass, which will not be corroded, and no painting is needed. They can be used for a long time with very low maintenance cost.
10) The cooling tower fill sheet adopt PVC material and heat-resisting.
The temperature in the water is up to 54. C and the special structure enables the water to touch the film in the biggest area with low air resistance. The energy exchanging efficiency is very high.
P Models | Flow(m3/h) | Fan D (mm) | Theoretical air quantity (m3/h) | Motor power (KW) | Motor Ranting current (A) |
SF-6T | 6 | 584 | 3400 | 0.25 | 1.0 |
SF-8T | 8 | 584 | 4500 | 0.25 | 1.0 |
SF-10T | 10 | 584 | 5700 | 0.25 | 1.0 |
SF-12T | 12 | 584 | 6800 | 0.25 | 1.0 |
SF-15T | 15 | 760 | 9100 | 0.37 | 1.4 |
SF-20T | 20 | 760 | 11300 | 0.55 | 2.0 |
SF-25T | 25 | 884 | 15000 | 0.55 | 2.6 |
SF-30T | 30 | 884 | 17000 | 1.11 | 2.6 |
SF-40T | 40 | 884 | 13000 | 1.1 | 3.6 |
SF-50T | 50 | 1190 | 18000 | 1.5 | 4.4 |
SF-60T | 60 | 1190 | 33000 | 1.5 | 5.2 |
SF-70T | 70 | 1470 | 40000 | 1.5 | 5.2 |
SF-80T | 80 | 1470 | 45000 | 2.2 | 7.7 |
SF-90T | 90 | 1470 | 50000 | 2.2 | 7.7 |
SF-100T | 100 | 1800 | 57000 | 4 | 8.8 |
SF-125T | 125 | 1800 | 70000 | 4 | 8.8 |
SF-150T | 150 | 1800 | 85000 | 4 | 8.8 |
SF-175T | 175 | 1800 | 99000 | 4 | 8.8 |
SF-200T | 200 | 1800 | 113000 | 5.5 | 12.6 |
Stuff
Installation Notes:
1. Reference the operation quality of the cooling tower, and checking the safety coefficient of foundation bearing capacity.
2. Should not be installed on the smoke, heat, open flame.
3. Should not be installed on the presence of corrosive gas.
4. Cooling tower of the vent and the distance between the obstacles should be more than 3 m.
5. Circulating water pump suction part should be set below the position of the cooling tower pond water.
6. Should be set pipeline stages, the cooling tower don't directly pipeline under weight.
7. The function of the cooling tower circulating water related, should check whether the reach regulation
8. Regularly check the cooling tower water level, water temperature, the motor power, voltage, and cooling tower vibration and noise, etc.
9. Winter operation should pay attention to not use ventilation window, easy is covered with ice and snow, cold water circulation, may cause the water system and packing frozen.