string wound flter cartridge(cotton or pp)
Type:filter | Medium Material:cotton | Place of Origin:Hebei China (Mainland) | Brand Name:SF |
function:filtration&purification | material:cotton or pp |
STRUCTURE
String wound filter cartridge consists of multi-hole frames wound closely with textile fibers. Diverse kinds of filtering precision can be realized by controlling the winding density. As the outer bore diameter is larger than the inner one, the filter cartridges have a good deep-level filtering capability.
FEATURES
Eliminate effectively the suspended objects and particles in the liquid. With large flow and small pressure loss. With high residual loan and long service life. Can resist higher filtering pressure. Provide different kinds of materials for filter cartridge according to the nature of liquid to be filtered, thus ensuring the good compatibility between them.
MAIN TECHICAL SPECIFICATION
Dimension: Outer diameter Ø65±2mm Inner diameter 28mm 30mm
Pressure: 0.5MPa
Temperature: 60°C(for polypropylene)
120°C(for stainless steel core, cotton fiber)
FLOW OF FILTER CARTRIDGE
The recommended flow for the filter cartridges in service is shown in the table (L/h for a 250mm filter cartridge)
micron rate (μ m) | Viscosity | ||||
1cs(water) | 30cs | 60cs | 120cs | 250cs | |
0.5 | 70 | 60 | 40 | 25 | - |
1 | 150 | 90 | 60 | 40 | - |
3 | 300 | 120 | 80 | 50 | - |
5 | 500 | 170 | 120 | 60 | 45 |
10 | 800 | 300 | 140 | 70 | 60 |
20 | 1100 | 540 | 220 | 100 | 95 |
30 | 1200 | 670 | 300 | 150 | 130 |
50 | 1200 | 880 | 440 | 180 | 160 |
75 | 1200 | 1200 | 690 | 230 | 200 |
100 | 1200 | 1200 | 750 | 270 | 220 |
Note:
1. The flow of each 250mm filter cartridge should not exceed 1200 L/h, otherwise its precision may be affected.
2. The flows shown in the above table are only the recommended values. The actual flow of the filter cartridge in service may change due to the liquid nature, temperature, the nature of the eliminated particles, the contents of the particles, etc.
3. It is recommended that a new filter cartridge used in the first time should work under a pressure drop of 0.1--0.3 bar, while the final pressure drop for the filter cartridge exchange is set at 2.5 bar. For the filter cartridge whose precision is lower than 10μm, the pressure drop for the filter cartridge exchange had better be set at 1.0--1.5 bar.
APPLICATION
Mainly used for the purification of water treatment in food and drinks, electronic, pharmaceutical, petroleum and chemical industries.
Packaging Detail:standard exported carton packing or according to clients' requirements |
Delivery Detail:within two weeks |