Sterilization Retort Sterilizer Equipment/machine
Processing:Sterilizer,sterilizing | Condition:New | Place of Origin:Shanghai China (Mainland) | Brand Name:xc |
Model Number:xc-1000*3000 | Processing Types:Carbonated Beverage | Voltage:made to order | Power(W):15 kw |
Weight:450 kg | Dimension(L*W*H):1200*3000 | Certification:CE | Warranty:12 months |
After-sales Service Provided:Engineers available to service machinery overseas | SUS304:stainless steel |
High Quality Hot Water Spray Retort
1.made of stainless steel 304
2.DN1000*2000mm
3.how water spray type
4.steam heating
Hot Water Spray Autoclave adopts hot water forced circulation to sterilize canned food. The thermal shock to package is small. Compressed air and steam pass into the pot at the same time automatically control sterilization temperature and pressure, the control accuracy is high, and it can prevent container from reformatting and damaging. It is suitable for sterilization of flexible retort pouches, glass bottles, plastic bags, plastic bowls, and other canned food. In sterilization process, the sterilization pot should fill with heating medium (hot water), cans or bottles are always immersed in water (it is also known as immersion). Automatic is the valve action in sterilization process, heating, cooling, security pressure are all processed automatically, until the end of the process.
Summary of Autoclave
Hot Water Spray Autoclave adopts hot water forced circulation to sterilize canned food. The thermal shock to package is small. Compressed air and steam pass into the pot at the same time automatically control sterilization temperature and pressure, the control accuracy is high, and it can prevent container from reformatting and damaging. It is suitable for sterilization of flexible retort pouches, glass bottles, plastic bags, plastic bowls, and other canned food. In sterilization process, the sterilization pot should fill with heating medium (hot water), cans or bottles are always immersed in water (it is also known as immersion). Automatic is the valve action in sterilization process, heating, cooling, security pressure are all processed automatically, until the end of the process.
Classification of Autoclave
Structure of Autoclave
Usages of Autoclave
Characteristics of Autoclave
Technical parameters of Autoclave
Volume | 600L | 1100L | 1900L | 2200L | 3100L | 4000L |
Body diameter (mm) | 800 | 900 | 1000 | 1100 | 1100 | 1200 |
Body length (mm) | 1000 | 1500 | 2000 | 2000 | 3000 | 3000 |
Material | SUS304/ Q235-B | |||||
Designed pressure | 0.35MPa | |||||
Working pressure | <0.3MPa | |||||
Designed temperature | 140.7°C | |||||
Working temperature | <135°C |
Packaging Detail:standard wooden case |
Delivery Detail:45 working days |