SAT230001 BSC-1300IIA2 Class 2 Bio Safety Cabinet

BSC-1300IIA2 Class 2 Bio Safety Cabinet, 1.Vertical Laminar Flow, 2.70% air circulation,30% air exhaust, 3.SUS304, 4.TUV:CE - details see: https://www.machineto.com/sat230001-bsc-1300iia2-class-2-bio-safety-cabinet-10207952
Place of Origin:Jiangsu China (Mainland)Brand Name:AIRTECHModel Number:BSC-1300 II A2After-sales Service Provided:No overseas service provided
Cleanliness:HEPA:ISO Class 5(Class100) /ULPA:ISO Class4(Class10)Filtration Efficiency:HEPA:>=99.995%,@0.3μm/ULPA:>=99.999%,@0.12μmDownflow Velocity:0.35Inflow Velocity:0.55
Power Supply:<=60Lumin.:>=800Air Direction:Top out 
SAT230001 BSC-1300IIA2 Class 2 Bio Safety Cabinet
contact supplier for SAT230001 BSC-1300IIA2 Class 2 Bio Safety Cabinet


SAT0307 BSC-1300IIA2 Bio Safety Cabinet

Characteristics

1.Approved by YY0569 of Chinese SFDA Class II,
Type A2 Biological Safety Cabinet of American NSF/ANSI49
2.Vertical lamina airflow, 70% air circulation, 30% air exhaust.
3.HEPA and ULPA with NO LEAKING(Patent No.ZL200820109130.9)in air
supply and exhaust system, ensure the cleanliness of ISO Class 5 (Class 100)
or ISO Class 4(Class 10)
4.Negative pressure and double layers Chamber with SUS work area.
5.The viewscreen of gradient of 10 make it comfortable to operate.
6.Demoutable circular-arc shelf can alieviate working tiredness and make it
easy to transport.
7.Non-obstructive air return mode in the front suction channel(Patent No.ZL200520140353.8).
8.Touchable control panel and LCD,flow indicator and waming.
9.Photoelectric alarm for sliding door and light.
10.Interlocked light and sterilizing.
11.Anti-splash safety spare socket and junction valve.
12.Intelligent auto-supply system ensures the change of air volume less
than 10% when the resistance of filter increases 50% and enhance safety.
13.Leak detection in cabinet, no leakage at 500Pa.
14.Leak detection in HEPA/ULPA, leaking ratio is <=0.01%
(scanned), <=0.005%(not scanned).

Model and ItemBSC-1300 II A2
CleanlinessHEPA:ISO5(Class 100)/ULPA: ISO4(Class 10)
Filtration EfficiencyHEPA:>=99.995%,@0.3 μm /ULPA:>=99.999%,@0.12 μm
Downflow Velocity0.35
Inflow Velocity0.55
Noise<=60
Power Supply~220V,50Hz
Operator Protectiona.Total colony in impaction sampler <=10CFU./time

b.Total colony in slot sampler <= 5CFU./time

Product ProtectionTotal colony in culture dish <=5CFU./time
Cross ContaminationTotal colony in cultere dish <=2CFU./time
Power(with spare socket)2.1
Weight300
Work Dimension1270*600*620
Overall Dimension1500*790*2050
Size and Qty. of Light36*2
Size and Qty. of UV Light30*1
Lumin.>=800
Air DirectionTop out

WHY US?

The Quality We Provide - Outstanding Quality Assurance

Control from production process:

•Processing workshop - equipped with advanced sheet metal chassis machining centers imported from USA and Japan

•Surface coating workshop –equipped with international first-class coating production lines and adopting high-quality coating materials of international brands;

•The surfaces are uniform, smooth, and antistatic

•General assembly and component assembly – in controlled environments

•Products supply–the company has sufficient capabilities for designing and manufacturing, being able to guarantee timely delivery for customers

•Stocks of all standard products are available, and non-standard products can be supplied in two to four weeks

Control from inspection:

•Microbiological test (microbiological testing laboratories certified by the relevant organization in Japan)

•Cabinet airtight test

•The tests of inhalation airflow velocity, decreased airflow velocity and airflow uniformity (air speed and volume testing system)

•Test of smoke tracing of airflow patterns (ultrasonic atomizer, fog generator)

•HEPA/ULPA filter leakage detection (aerosol experiments, U.S. imported 0.1 μm large-flow particle test system)

•Noise detection (noise-damped environment and specialized instruments)

•Light intensity test

•Fan performance test (digital photo-electromotive balance detection system)

•Vibration detection (vibration detector)

•Electrical safety test (in line with the electrical safety standards for active medical equipment)

The Service We Provid - We Take Care Of Your Order

Punctual delivery time:

•We put your order into our tight production schedule, ensure your punctual delivery time.

•Production / inspection report before your order packed.

•Shipping notice/ insurance to you as soon as your order is shipped.

After sales service:

•We respect your feed back after receive the goods.

•We provide 0-12 months warranty after goods arrive.

•We promise all spare parts available in lifetime use.

•We lorge your complain within 48hours.

Professional sales:

•We value every inquiry sent to us, ensure quick competitive offer.

•We cooperate with customer to bid tenders. Provide all necessory docuement.

•We are a sales team, with all techinical support from engineer team.

SAT230001 BSC-1300IIA2 Class 2 Bio Safety Cabinet
Packaging Detail:plywood case
Delivery Detail:35 days

Related Product for SAT230001 BSC-1300IIA2 Class 2 Bio Safety Cabinet