Sanitary Common/Aspesis Sample Valve
Place of Origin:Jiangsu China (Mainland) | Brand Name:no | Model Number:XH | Material:Stainless Steel |
Working principle
XH axenic snifting valve can be sterilize every time before and after the sampling.
Valve Open:sampling
Manual valve can be opened by turning the opening handle (adjustable valve) or the driving lever (open/close valve).Here,the valve lever and diaphragm retract and the liquid flows in.
Valve closed:sterilization
Reverse the procedure and close the valve.For steaming sterilization,we suggest to install a small decompression valve (by user's option) at the outlet of the valve.
Standard design
XH axenic snifting valve consists of three parts:valve body,valve head and diaphragm...
Put the rubber diaphragm on the top of the valve head lever for the telescopic motion...
Valve bodies and valve heads can be exchanged among all the valve models.
Valve body include types of
Weld-throat section for container installation,weld-throat section for pipeline installation,wld-throat section with clip and weld-throat section with screw thread.
Technical parameter
Max.working pressure:
At valve base (Max.working pressure at valve closed) 1000 kPa (10 bar)
At valve cover (valve open):stainless steel 1000kPa(10 bar)
Temperature
Max.sterilization temperature,drying steam(2-3bar):121 - 134 degree
Packaging Detail:plastic bag first and then packaged in paper box |
Delivery Detail:according to the quantity of order |