Rooftop Package Air Conditioner For HVAC System

1.Rooftop Air conditioner, 2.Hermetic scroll compressor, 3.Cooling capacity:10~35kw, 4.R22,R407C,R134A, 5.High static pressur - details see: https://www.machineto.com/rooftop-package-air-conditioner-for-hvac-system-10208588
Type:Air Conditioner Parts,Air Conditioning FittingApplication:IndustrialCertification:CEPlace of Origin:Shanghai China (Mainland)
Brand Name:ShenglinModel Number:GT-WKR-10tube material:copper, aluminium, steel, stainless steel be viablefin material:copper, aluminium, steel, stainless steel be viable
design serice:be viable   
Rooftop Package Air Conditioner For HVAC System
contact supplier for Rooftop Package Air Conditioner For HVAC System


Rooftop Package Air Conditioner For HVAC System

1. Air cooled rooftop air conditioner.

2. Cooling capacity: 8kw to 90kw, a variety of choices.

3. High external pressure.

4. Applicable to residential and commercial buildings, hotels, and scientific research units, factories and

enterprises and so on.

Type

Roof Top AHU Specification

Model

GT-WKR-10

Specification

Cooling capacity 1*

kW10.5

Heating capacity 2*

kW11.5

Supply air 3*

m3/h1800

Static pressure 3*

Pa100

Noise 4*

dB(A)60

Power

3N-380V-60Hz

Total capacity

3.9

Color

White

Cooling system

Compressor

Type

Efficient scroll closed

Quantity

1

Supply air fan

Type

Low noise centrifugal type
CapacitykW0.37

Evaporator

Type

Inner grooved copper tube and aluminum fin

Fin type 5*

Slotted fin hydrophilic aluminum fin

Condenser

Type

Inner grooved copper tube and aluminum fin

Fin type 5*

Rippled hydrophilic aluminum fin

Condenser fan

Type

Low noise axial type

Quantity

1

Refrigerant

Refrigerant

R22/R407C

Refrigerant control

External balance type thermal expansion valve

Air filter

Initially effect plate filter

Dimensions

L

mm

1400
W

mm

1050
H

mm

1050

Weight

kg

200

Note:

1. Cooling condition: Indoor dry bulb/wet bulb:29/19°C,Outdoor dry bulb/wet bulb:46/24°C

2. Heating condition:Indoor dry bulb/wet bulb:20/—°C;outdoor dry bulb/wet bulb:7/6°C;

3. The air volume and static pressure`s specification in the table is standard, and can be designable.

4. Noise data is measured in the front of the units when cooling under the standard air volume.

5. Fin type and material can be designable.

1. Evaporator: Type Inner grooved copper tube and aluminum fin

2. Fin Type 5* :Slotted fin hydrophilic aluminum fin

3. Condenser: Type Inner grooved copper tube and aluminum fin

4. Fin Type 5* :Rippled hydrophilic aluminum fin

5. Condenser Fan Type: Low noise axial type

For further information please feel free to contact us.

Ms. Bella Gong

Tel: +86 21 35324169-209

Mob: +86 13916251589

Skype: sales2shenglintec.com

Rooftop Package Air Conditioner For HVAC System
Packaging Detail:customerized packing
Delivery Detail:one month

Related Product for Rooftop Package Air Conditioner For HVAC System