Refrigeration air dryer

Refrigeration air dryer, Good separation, Drainage stable and reliable, High inlet temperature, Dew point temperature is low - details see: https://www.machineto.com/refrigeration-air-dryer-10294396
Type:Refrigeration compressor, refrigerated air dryerPlace of Origin:Guangdong China (Mainland)Brand Name:AEOMACHINEModel Number:AEO-200 SG
Capacity:28 Nm3/minCompressor power:4.4 kwFan motor:720 wExport path:R3
Dew point:2-5 centigrade degreeRefrigerant:R12,R22,R134A,R407C,R410A etc.Application:refrigeration compressed air dryerCompressor brand:Panasonic
Compressed air temperature at inlet:60 centigrade degreeCooling model:air cooling, water cooling  
Refrigeration air dryer
contact supplier for Refrigeration air dryer


Refrigeration air dryer performance:

Frozen ability

Refrigerant compressor with the power to fully pre-cooling, heat and then cooling. Treatment than similar products in the largest 30%.

Good separation

Built in high efficiency separator, and then a variety of conditions, can be separated efficiently remove more than 99% of compressed air condensate and most of the solid particles and oil.

Drainage stable and reliable

Electronic self-draining valve filter configuration, coupled with the unique interception, to ensure reliable water.

High inlet temperature

But with a pre-cooler, the whole big area of heat exchanger copper control. Directly into the 80°C below the air temperature.

Dew point temperature is low

High performance evaporator, large heat transfer area, so that compressed air in the evaporator for a long time, to ensure adequate heat exchange, allows more gas to form droplets of hydrogel to maintain the best drying results.

Automatic adjustment

Efficient cooling system, high and low temperature environment is not automatically adjust the high jump is not frozen, always keep the best drying results.

Stable

From Japan, Denmark and other countries brands accessories, Quality Assurance.

Cold drying machine principle

Factors exhibited a general atmosphere of water vapor, not easy to detect its existence, but by the air compressor compression and cooling piping, will be condensed into liquid water droplets; such as air temperature at 30 ° C 75% relative humidity conditions, excretion 3Nm3/min, work pressure 0.7Mpa Compressed air for about 24 hours running with 100L of water. The water must be effectively removed, otherwise it will cause pipeline corrosion and pneumatic tool components, instrument damage inaccurate, good product quality, equipment failure seriously affect the production process, increase production costs and other undesirable consequences of the compressed air is cold and dry machine reduce certain temperature so that the compressed air in the water at this temperature precipitation, separated by separator, auto drain valve by the discharge, so that compressed air was drying.

Refrigeration air dryer
Packaging Detail:Standard export carton or wooden case 1pcs/box
Delivery Detail:Within 20 days after receiving advance payment

Related Product for Refrigeration air dryer