Quenching Furnace
Condition:New | Type:Induction Furnace | Usage:Melting Furnace | Place of Origin:Zhejiang China (Mainland) |
Brand Name:Shenguang | Model Number:KGPS/IGBT | Voltage:custom-order | Power(W):custom-order |
Dimension(L*W*H):custom-order | Weight:0.5T-20T | Certification:ISO9001:2000;CE | Warranty:According to the contract |
After-sales Service Provided:Overseas service center available | Capacity:10kg~50ton | Tiling:hydraulic tilting or gear reducer | Input Frequency:50Hz or 60Hz |
Cooling manner:Water cooling | Transformer capacity:450KVA~4000KVA | Melting Rate:0.055T/H~30T/H | Rated Power:100KW~1200KW |
Power Consumption:430KWH/T~650KWH/T | Processing Type:Quenching | Working Frequency:500Hz~8000Hz |
Quenching Furnace
·Application
This series Induction Furnace, steel shell mechanical tilt, is for melting cast steel, cast iron, stainless steel, copper, aluminum and other metals or its alloy.Induction Furnace also be used together with self-heated furnaces and electric arc furnace for heating or keeping warm/holding the molten iron and molten steel.
Induction Furnace is particularly suited to small and medium-size enterprises, or as Precision Casting Material Test
·Electrical Feature
1.Induction Furnace frequency-sweep zero voltage start, high success rate, no shock.
2.Induction Furnace automatic resistance adjustment, permanent power output, 10-20% energy saved in comparison with domestic traditional machine of the type.
3.Auto phase sequence adaptation, free of synchronization.
4.Good performance in reload staring, auto recovery; 5.Highly integrated in controlling circuit, free of use of high-rate starter and relay loop, fairly low failure rate.
6.Wholly digital design, strong in anti-interference, no temperature shift when induction furnace is in continuous working.
7.Multi-protection functions (for over current, over voltage, insufficient water pressure, power failure, or phase absence), and mishandling will not cause damage to machine.
·Technique data of Quenching furnace
Furnace Model | Rated Power (KW) | Working Frequency (KHZ) | Transformer Capacity (KVA) | Cooling Method |
PR-100 | 100 | 0.8-8KHZ | 450 | Water Cooling |
PR-150 | 150 | 950 | ||
PR-250 | 250 | 1500 | ||
PR-350 | 350 | 2000 | ||
PR-550 | 550 | 3200 | ||
PR-800 | 800 | 3600 |
Packaging Detail:Plywood case or nude |
Delivery Detail:15 days to 40 days |