PR50 Dual Pulse Programmable Spot Welding Machine/ Spot Welder
Condition:New | Place of Origin:Guangdong China (Mainland) | Brand Name:GEB | Model Number:PR50 |
Dimensions:560*420*315mm | Weight:42kg | Usage:NiMh,lithium | Voltage:220V |
Power(W):12KW | Warranty:one year | After-sales Service Provided:Overseas third-party support available |
PR50 Dual Pulse Programmable Spot Welding Machine/ Spot Welder
1. Function and Feature
Built-in 8 bit micro Processor and advance unique software application to achieve precision and high quality Spot weld Joints; User-friendly touch membrane-switch panel operate, digitally displays all setting for easy operation and less set-up time and dual pulse power can be regulated by User-friendly touch membrane-switch panel, and adjustable weld times and multiple pulses, store ten weld schedules.
2.Application:
Suitable for Various batteries and taps, Welding range from button cell to cylinder battery, Including NI-CD,NI-MH and Lithium-ion etc.Application tabs including pure nickel and nickel plated steel.
Input Voltage | 220V/50Hz(60Hz) | ||||
Input Current | 30A | ||||
Input Pressure | 10Bar | ||||
Output Voltage | 5.5V | ||||
Rate Power | 12KVA | ||||
Max. output Current | 1800A | ||||
Welding Time/Band | 20ms/Band | ||||
Welder Speed | Approx.120times/min | ||||
Item | Abort status | Reason Example | settling aborts way | ||
1 | Electrodes can not down | No Pressed-air input | Start the air-pump | ||
AIRTECH solenoid Valve damaged | Change the same part | ||||
Foot-Switch damaged | Change foot-switch | ||||
SMC Cylinder damaged | Change the same Cylinder | ||||
down speed adjusting Copper-screw locked | Open it | ||||
2 | Electrodes can not up | AIRTECH solenoid Valve damaged | Change the same part | ||
Up speed adjusting Copper-screw locked | Open it | ||||
3 | Continuance display “Hot Hot” | The welder Over heat protecting | Shut off the power, Cooling the welder | ||
4 | Start the Power but no display | The power open | Check it | ||
2A fuse open | Check it and change | ||||
5 | Weld-Head up and down, But no firing | Check “WELD Led Lamp” is on or off | Touch “r” keypad open it | ||
The fuse is open Inside the welder | Move the Welder cover and check it, change it | ||||
Light-Control Switch abort inside the Weld-Head, Then check it according the following step | Tread the foot-switch ,make the electrodes down to the tabs ,then check “ALARM Led Lamp” is on or off, If “on” that no problem, “off” must be change it. | ||||
The electrodes Pressure too big | If the electrode pressure on the Tabs can not reach the user set pressure, joining weld will be happened, Therefore Operator must rise up the work pressure or reduce the electrode pressure only |