Plate Heat Exchanger (dairy equipment, juice equipment)
Processing:Heat Exchanger | Place of Origin:Zhejiang China (Mainland) | Brand Name:kingpak | Processing Types:Milk |
juice equipment:beverage equipment |
Plate Type Heat Exchanger (dairy equipment, juice equipment)
Plate heat exchanger is composed of two different temperatures of fluid through the siding and cooling by indirect heat exchange the ideal equipment with high efficiency heat exchanger, heat recovery, thermal loss, small footprint, and assembled flexible, simple, Washable easy installation, long life, low investment and use of safety features.
Applied to the food and beverage processing:
1) Various types of dairy products: milk, milk powder, milk beverages, yogurt, etc.;
2) Plant protein drink: peanut milk, milk tea, soy milk and soy milk drinks;
3) Fruit juice drinks: fresh juice, fruit tea, etc.;
4) Cool tea drink: tea, reed rhizome drinks, fruit and vegetable drinks;
5) Seasoning: soy sauce, vinegar, tomato juice, sweet chili sauce, etc.;
6) Wine products: beer, wine, rice wine, wine and other alcoholic;
Used in other industrial fluids processing: Pharmaceutical / dyeing / HVAC heat / chemical / power / heated swimming bath oil / metallurgy / hot water / marine / mechanical / heat recovery / paper / textile / geothermal / green / refrigeration.
Plate Sheet Type | BR0.05 | BR0.1 | BR0.2 | BR0.3 | BR0.5 |
Plate Sheet Material | SS304 or SS316 | ||||
Single Heat Exchange Area(m²) | 0.05 | 0.1 | 0.2 | 0.3 | 0.5 |
Plate Sheet Size(mm) | 500*168 | 660*250 | 970*330 | 365*1183 | 450*1451 |
Plate Sheet Thickness(mm) | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 |
Angle Hole Diameter(mm) | 38 | 60 | 75 | 85 | 110 |
Connect Pipe Diameter(mm) | 28 | 38 | 46 | 90 | 116 |
Corrugation Form | "Y" type | ||||
Corrugation Space Between(mm) | 10 | 12 | 12 | 14 | 16 |
Average Plate Space Between(mm) | 3.8 | 3.8 | 3.8 | 4.5 | 4.5 |
Combined Heat Exchange Area(m²) | 0.5~3 | 3~10 | 8~38 | 30~50 | 40~80 |
Max. Pressure (Mpa) | 0.4~2 | ||||
Max. temperature (°c) | Common:120-160 Especial:250 | ||||
Heat Transfer Coefficient(w/ m² °c) | 2000-6000 |
Structure
Combination plate
Model
Flow Process Model:
Plate heat exchanger temperature and flow according to the media, can be assembled into a single process, double-flow, three processes, and multi-process forms. Medium in a single process is a process flow heat exchanger, dual process is the exhumation of medium in the heat exchanger flows through the two processes, and so on. When using multi-process, the heat exchanger of the four interfaces can not be on the same side of the clamping plate, both before and after the inlet and outlet should be located in the clamping plate.
Packaging Detail:wooden box or film |
Delivery Detail:in 10 days after receive the deposit |