Oxyhydrogen Flame Ampoule Filling and Sealing Machine ABS200,ABS300
Place of Origin:Hunan China (Mainland) | Brand Name:OKAY ENERGY | Model Number:ABS200,ABS300 | Application:Liquid |
Type:Filling Equipment | AC Voltage:220/110 V | Power Consumption:0.8~1.2kw/h | Current:single phase |
Dimensions - L*W*H:620*280*360mm, 780*280*520mm | Gross Weight:33kg,28kg | Color:Blue | Suitable Ampoule Bottle:ABS200 for 1~10ml,1~5ml is the best; ABS300 for 1~20ml |
Is_customized:Yes | Certificate:CE |
Description of Ampoule Filling and Sealing Machine:
Oxyhydrogen Flame Ampoule Filling and Sealing Machinetechnology uses water as medium to electrolyze water into H2 and O2, fire them to formed Oxyhydrogen Flame. The temperature of Oxyhydrogen flame is as high as 2800 degrees so that it can seal the Ampoules very fast. The quality and speed of Oxyhydrogen Flame sealing method is higher than Liquid gas's.
Oxyhydrogen FlameAmpoule Filling and Sealing Machinecompared with traditonal liquid methods:
1. Safety:
Oxy-hydrogen Flame Ampoules Sealing Machine just uses water and electricity, no gas bottle, no hydrogen gas storage, no leakage and explosive danger.
2. Convenience:
it can work just with water and electricity, every litre water can be used 7~8 hours. But Liquid gas bottle need to be changed by manual moving, it is very inconvenient.
3. Cleanliness:
Oxy-hydrogen combustion just produces little water vapour, there is no harm to the pharmaceuticals. But Liquid gas combustion produces carbon dioxide, carbon monoxide and nitrogen compounds which will impact on the quality of pharmaceuticals.
4. High Efficiency:
The speed of Oxy-hydrogen Flame sealing method is higher than Liquid gas's.
Operation ofOxyhydrogen FlameAmpoule Filling and Sealing Machine:
1. Install the Oxyhydrogen Flame Ampoule Filling and Sealing Machineaccording to the Operating Instruction, then connect the pipe, adjust position up and down.
2. Open the Power Supply switch of OxyhydrogenFlame Ampoule Filling and Sealing Machine, start to produce gas, when the air pressure rises to 0.1Mpa, you can open the torch valve.
3. Firing to formed Oxyhydrogen Flame, can adjust flame size further through valve adjustment.
Remark: When firing, pls don't let any part of the body be in front of the torch nozzle.When firing, you should be in the side of the torch to avoid firing your hands.
4. Using the tweezer attached with machine to nip ampoule, the tautness of nipping should guarantee the ampoule not only won't come off, but also can rotate it with hand.
5. To put the ampoule in Oxyhydrogen Flame to heat and rotat it at the same time. When heating is finished, pull up the tweezer, the process of sealing is accomplished.
Accessories :
Oxyhydrogen Flame Ampoule Filling and Sealing Machine: 1 set
soft pipe : 2m
Flame arrester: 1 unit
Holder:1 piece
Technical Paremeters:
Model Number | ABS200 | ABS300 |
AC Voltage Requirement (V) | 220/110 | 220/110 |
Phase | single | single |
DC Voltage &Current (A) | 5V 60A | 5V 60A |
Rated Power(kw/h) | 0.8 | 1.2 |
Max. Gas Output(L/h) | 200 | 300 |
Max. Working Pressure (kg/cm2) | 1.3 | 1.3 |
Max. Water Consumption (L/h) | 0.11 | 0.17 |
Water Feed | manual | manual |
Max. Flame Modifier Consumption (L/h) | 0.1 | 0.15 |
Flame Modifier Feed | manual | manual |
Dimensions - L*W*H (mm) | 620*280*360 | 780*280*520 |
Gross Weight (kg) | 33 | 38 |
Ventilation Space Requirement (mm) | 200 in each direction | 200 in each direction |
Suitable Ampoule Bottle | 1~10ml,1~5ml is the best | 1~20ml |
Packaging Detail:Standard Export Carton Packing |
Delivery Detail:15-20 working days after 30% deposit |