Minimal Filter Fan FF 018

1.Very low noise, 2.Minimal depth in enclosure, 3.Functional design, 4.Time-saving installation, 5Weather proof and UV resistant - details see: https://www.machineto.com/minimal-filter-fan-ff-018-10229710
Place of Origin:Zhejiang China (Mainland)Brand Name:SaipModel Number:FF 018IP:54
Minimal Filter Fan FF 018
contact supplier for Minimal Filter Fan FF 018


Filter fans are used to provide an optimum climate in enclosures. The interior temperature of an enclosure can be reduced by channelling cooler filtered outside air into the enclosure thus expelling heated internal air. The resulting air flow prevents formation of localised hot pockets and protects the electronic components from overheating. Tne plastic used for the hood of this filter fan series is highly weather proof and UV light resistant.

Technical Data
Axial fan, ball bearingservice life 50 000h at 25°C /77°F(65%RH)
fan body aluminium, rotor plastic
Connection2 wires with pressure clamps 2.5mm², length 100mm
Casing (filter fan and exit filter)plastic according to UL94 V-0, light grey
Hood (filter fan and exit filter)plastic according to UL94 V-0, light grey, weather proof and UV light resistant according to UL746C (f1)
Mounting framewith double-side industrial adhesive band for fixing to the outside of enclosure; certain operating circumstances can make the additional use of screws necessary (see drilling template); included in the delivery of the filter fans is a template for the enclosure cut-out.
Filter matG4 acc. to DIN EN 779, filtering degree 94%
Filter materialsynthetic fibre with progressive construction, temperature resistant to 100°C, self-extinguishing class F1; moisture resistant to 100% RH; reusable - cleaning by washing or vacuuming
Operating/Storage temperature-10 to +70°C (+14 to +158°F) / -40 to +70°C (-40 to +158°F)
Operating / Storage humiditymax. 90 % RH (non-condensing)
Protection type/Protection classIP55 / I (earthed)

Special features

  • Theself-adhesive sealof the mounting frame prevents dust and water from entering the cabinet.
  • Functional designof the intake and exit fan hoods very effectively prevents direct intrusion of falling water and dust. The advantage is that the filter mat does not get so quickly contaminated with dirt and thus does not need to be exchanged so often.
  • Theair channelingmakes the filter fan particularly quiet in operation.
  • Functional andmodern designenables time-saving assembly and maintenance. EMC versions and other voltages on request.
  • Thedirection of air flow can easily be switchedby reversing the axial fan (sizes 1 to 3)

Art. No.Operating voltageAir volume, free flowAir volume with exit filterCurrent consumptionPower consumptionAverage noise level (DIN EN ISO 4871)Depth in enclosureEnclosure cut-outWeight (approx.)Approvals
01800.0-00230VAC, 50Hz21m³/h16m³/h80mA13W31db (A)45mm97 x 97mm + 0.40.6kgVDE + UL File No. E234324
01801.0-00230VAC, 50Hz55m³/h42m³/h100mA15W40db (A)58mm125 x 125mm + 0.41.0kgVDE + UL File No. E234324
01802.0-00230VAC, 50Hz102m³/h68m³/h100mA15W39db (A)86mm176 x 176mm + 0.41.3kgVDE + UL File No. E234324
01800.0-01120VAC, 60Hz24m³/h18m³/h160mA13W31db (A)45mm97 x 97mm + 0.40.6kgUL File No. E234324
01801.0-01120VAC, 60Hz63m³/h48m³/h180mA15W40db (A)58mm125 x 125mm + 0.41.0kgUL File No. E234324
01802.0-01120VAC, 60Hz117m³/h78m³/h180mA15W39db (A)86mm176 x 176mm + 0.41.3kgUL File No. E234324

....