MincoA3 AMF ATS Generator Controller CE certification

MincoA3 AMF ATS Generator Controller has ATS control function,when city mains failure,AMF generator,display status of generator - details see: https://www.machineto.com/mincoa3-amf-ats-generator-controller-ce-certification-10231978
Place of Origin:Guangxi China (Mainland)Brand Name:MincoModel Number:A3Engine Type:Diesel
Type:Engine ControllerName:MincoA3 AMF ATS Generator ControllerWarranty:3 yearsDisplay:LED
Certification:CE   
MincoA3 AMF ATS Generator Controller CE certification
contact supplier for MincoA3 AMF ATS Generator Controller CE certification


Minco A3 AMF ATS Generator Controller

TheFunctional Characteristics of MincoA3 AMF ATS Generator Controller.

1.Provides remote start port, time setting function of delayed start and

stop ;can control genset to start , stop and load automatically.

2.All the relay output contact capacity is over 10A.

3.Convenient ATS control function, with mains supply output

and genset emergency supply output.

4.Two connecting ways of Coolant temperature and oil pressure:

analog measurement and alarm switch

5.Auto-record the running time of genset.

6.Protection functions: low oil pressure, high coolant, over speed,

emergency stop and over crank, ect.

II. Minco A3 AMF ATS Generator Controller Control parameters

  1. Analog inputs: oil pressure sensor kind ,Coolant temp. sensor kind
  2. Switch inputs: remote start, emergency stop, high coolant temp, low oil pressure, alarm switch
  3. Switch inputs: Genset fault, fuel supply/stop,start,mains supply switch on,genset switch on, idle normal close/normal open/common
  4. System parameters settings: coolant temperature upper limit, oil pressure lower limit battery voltage lower limit, frequency upper limit, frequency lower limit, trip frequency, coolant temperature adjustment, oil pressure adjustment, battery voltage adjustment,no supply to load delay, warm-up delay, energize to stop (ETS) fuel delay, remote start delay, retransfer delay, cooling stop delay, idle speed start delay, idle speed stop delay, control parameter 1, control parameter 2, control parameter 3

III. Minco A3 AMF ATS Generator Controller External Features

Dimension:Front panel (L×WxD)96×96x9 mm
Back panel(L×WxD)84×84x50 mm
Mounting hole: (L×W)85×85mm
Power SupplyDC8-40 V< 300 mA
Working environment.: -25~70°C
Relative humidity.< 95%
N.W.380g

MincoA3 AMF ATS Generator Controller CE certification
Packaging Detail:carton
Delivery Detail:10 days upon recieved the payment.

Related Product for MincoA3 AMF ATS Generator Controller CE certification