LTWF Series Air Conditioning and Industry Cooling Air Cooled Chiller, Air Cooled Water Chiller, Air to Water Chiller

Air Cooled Chiller, -Air Cooled Water Chiller, -Air to Water Chiller, -Chiller for Air Conditioning&Industry, -No Cooling Tower - details see: https://www.machineto.com/ltwf-series-air-conditioning-and-industry-cooling-air-cooled-chiller-air-cooled-water-chiller-air-to-water-chiller-10243267
Condition:Chilled Water Inlet 12℃, outlet 7℃Type:Air-CooledPlace of Origin:Shandong China (Mainland)Brand Name:LYYTTE, OEM, ODM
Model Number:LTWFCooling Capability(kw):5-140KW (2TONS-40TONS)Voltage:380-460VCertification:CE,ISO
Warranty:1 YEARAfter-sales Service Provided:Engineers available to service machinery overseasApplication:Air Coditioning Central Cooling or Industry CoolingCooling Capacity:4KW-120KW/Unit
Compressor:Hermetic Scroll or Semi-hermetic Piston TypeEvaporator:Shell and Tube Type Evaporator or Tube in Tube TypeCondenser:Air Cooled V-Type or U-Type Condenser, Copper Tube and AL FinRefrigerant Control:Thermal Expansion Valve
Refrigerant Type:R22, R134a, R407c, R410a   
LTWF Series Air Conditioning and Industry Cooling Air Cooled Chiller, Air Cooled Water Chiller, Air to Water Chiller
contact supplier for LTWF Series Air Conditioning and Industry Cooling Air Cooled Chiller, Air Cooled Water Chiller, Air to Water Chiller


LTWF Series Air Cooled Chiller, Air Cooled Water Chiller, Air to Water Chiller for Air Conditioning and Industry Cooling

-Air Cooled Chiller /Air to Water Chiller for Air Conditioning Cooling or Industry

-Scroll Compressors(Copeland, Sanyo, Danfoss etc.) Units

-Semi-hermetic Piston Compressors(Bitzer etc.) Units

-R22, R134a, R407c, R410a refrigerant available;

-Shell and Tube Type Evaporator or Tube in Tube Type Evaporator

-Air Cooled V-Type or U-Type Condenser, Copper Tube and AL Fin;

-Refrigerant Control: Thermal Expansion Valve.

Air Cooled Chiller Features:

1.With scroll, or reciprocating compressor of high quality, high efficient heat exchangers, excellent system design, by excellent process, the chillers is of suffient capacity and efficiency.

2.The chillers will work stably for long time period as they are produced by excllent process, composed of reliable control components and professional control procedure.

3. Units with V type heat exchanger: panels, frame and base are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.

4.3-phase scroll type compressor, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.

5. External rotor type axial fans, equipped with three phase direct drive motors, low noise 8 poles, protection level IP54, provided with a protective outlet grille.

6. Evaporator built with high efficiency tube in tube type heat exchanger, factory insulated with flexible close cell material.

7.Condenser built with seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins.

8. Refrigerant circuit complete with charge valves, filter drier, sight glass, gas-liquid separator, thermostatic expansion valve high & low pressure switch.

9. Hydraulic circuit built with galvanized pipe, complete with water discharge connection for tube in tube heat exchanger and flange type hydraulic connectors in two directions easy for connections from both sides of the units.

10. Electric panel consist of: compressor contactor, fan motor contactor, compressor protection breaker, fan protection breaker, phase sequence relay and microprocessor with function display (display only for master/packaged unit).

11. Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.

12. Complete safety protection:

a. High&low pressure protection, pressure safety value protection;

b. Overload protection to the compressor;

c. Power supply protect for phase lack, counter phase, voltage too high and voltage deficient;

d. Water system protection for freezing breaking, water lack etc.

Applicable Industries

-Industrial Reaction Kettle Cooling

-Central Air Conditioning System

-Chemical Industry.

-Plastic Injection Cooling -Pharmaceutical Industry

System Diagram

Model Specifications: LTWF-68 A S E(P)

LT-LVTE Company Products Code

W-Scroll Type Compressor

F-Air Cooled Type Chiller

E-Built in Water Pump and Water Vessel; P-Built in Water Pump without Vessel; Empty-No Pump and Vessel

Model Details of Air Cooled Chiller

1. Design Cooling Condition: Chilled Water In/Out 12°C/7°C;Ambient 35°C

Models: LT03AS-40AD Cooling Capacity: 8KW-120KW

-Hermetic Scroll Compressors

-Tube in Tube Type Heat Exchanger for Evaporator

-V Type Fin Air Cooled Condenser

-Water Pump and Water Tank are an optional to built in the chiller

-Chilled Water Inlet/Outlet Temperature 12°C/7°C,Ambient 35°C

-Mostly Used for Central Air Conditioning Cooling

Remark: 1.Colling Condition: Chilled water in/out 12/7°C;Ambient Temperature 35°C;

2. Suitable chilled water temperature: 7-25°C;

3. Power supply: 3P-380V-50HZ; with voltage allowance±10%, voltage dif between the phase lines±2%;

4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;

5. There may be Changes for improvement without notice, confirm always before your order.

Remark: 1.Colling Condition: Chilled water in/out 12/7°C;Ambient Temperature 35°C;

2. Suitable chilled water temperature: 7-25°C;

3. Power supply: 3P-380V-50HZ; with voltage allowance±10%, voltage dif between the phase lines±2%;

4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;

5. There may be Changes for improvement without notice, confirm always before your order.

Low Temperature Models:

2.Cooling Condition: Chilled Glycol in/out -1/-5°C; ambient 35°C

Models: LT03ASL-40ADL Cooling Capacity: 4.7KW-61.6KW

-Hermetic Scroll or Semi-hermetic Piston Compressors

-Tube in Tube Type Heat Exchanger for Evaporator

-V Type Fin Air Cooled Condenser

-Water Pump and Water Tank are an optional to built in the chiller

-Chilled Glycol Inlet/Outlet Temperature -1°C/-5°C, Ambient 35°C

-Mostly Used for Industrial Processing Cooling

Remark:1.Designed Condition:Chilled Glycol in/out -1/-5°C; ambient 35°C;

2.This series units used in low temperature conditions, 25% ethylene glycol to be used as a refrigerant;

3.Power supply: 3P-380V-50HZ;with voltage allowance±10%,voltage dif between the phase lines±2%;

4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;

5.There may be Changes for improvement without notice, confirm always before your order.

Remark:1.Designed Condition:Chilled Glycol in/out -1/-5°C; ambient 35°C;

2.This series units used in low temperature conditions, 25% ethylene glycol to be used as a refrigerant;

3.Power supply: 3P-380V-50HZ;with voltage allowance±10%,voltage dif between the phase lines±2%;

4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;

5.There may be Changes for improvement without notice, confirm always before your order.

Finished Products of Air Cooled Chiller:

Products in Warehouses:

Products Certificate:

LTWF Series Air Conditioning and Industry Cooling Air Cooled Chiller, Air Cooled Water Chiller, Air to Water Chiller
Packaging Detail:Wooden Cases, Export Standard Packing
Delivery Detail:15-20days

Related Product for LTWF Series Air Conditioning and Industry Cooling Air Cooled Chiller, Air Cooled Water Chiller, Air to Water Chiller