LTLS Series Central Air Conditioning Cooling Water Cooled Chiller 100KW-3500KW

Water Cooled Chiller, -For Air Conditioning Cooling, -100-3500KW Cooling Capacity, -Screw Compressor Chiller, -CE, CRAA - details see: https://www.machineto.com/ltls-series-central-air-conditioning-cooling-water-cooled-chiller-100kw-3500kw-10243314
Condition:Chilled Water Inlet/Outlet 12℃/7℃Type:Water-Cooled,Water Cooled Type ChillerPlace of Origin:Shandong China (Mainland)Brand Name:LYTTE, OEM, ODM
Model Number:LTLSCooling Capability(kw):100-2000KWVoltage:380V-460VCertification:CE,ISO
Warranty:1 yearAfter-sales Service Provided:Engineers available to service machinery overseasCooling Capacity:30-500 TonsEvaporator:Shell and Tube Type Heat Exchanger
Condenser:Shell abd Tube Type Heat ExchangerCompressor:Semi-hermetic Screw TypeRefrigerant:R134a, R407C, R22Refrigerant Control:Thermal Expansion Valve
Usage:Air Conditioning CoolingAdvantage:Large Capacity Range for chosenCooling Tower:Yes 
LTLS Series Central Air Conditioning Cooling Water Cooled Chiller 100KW-3500KW
contact supplier for LTLS Series Central Air Conditioning Cooling Water Cooled Chiller 100KW-3500KW


LTLS Series Central Air Conditioning Cooling Water Cooled Chiller 100KW-3500KW for

-Cooling Capacity: 100KW-3500KW/Unit 30Tons-500Tons/Unit

-Compressors: Semi-hermetic Screw Type

-Evaporator: High Efficiency Shell and Tube Type

-Condenser: High Efficiency Shell and Tube Type; factory insulated with flexible close cell material.

-Refrigerant: R134a, R407C, R22 etc.

-Refrigerant Control: Thermal Expansion Valve

Model Specifications:

LT L S---30 W(R) S L(G)

LT--LVTE Company Products Code L--Screw Compressors S--Chiller, Cooling Only

30--Compressor HP W--Water Cooled R--With Heat Recovery S--Single Compressor

L(G)--Chiller Water(Glycol Water) Output Temperature;

L:Glycol Water in/out -1°C/-5°C; G-Glycol Water in/out -11°C/-15°C;None:Chilled Water In/out 12°C/7°C

Specifications of LTLS Series Water Cooled Screw Comperssor Chillers(Single Compressor Model)
MODEL LTLS-30WS40WS50WS60WS70WS80WS90WS100WS110WS120WS130WS140WS160WS180WS200WS
Cooling
Capacity
KW100136.5176233.6256319.2349.3378.1416.2495523572643.9749.9823.6
103kcal/hr86117151201220275300325358426450492554645708
Heat RecoveryKW3750658694116127138152180190208233271298
104kcal/hr3.24.35.67.48.11010.911.913.115.516.417.920.123.325.7
CompressorPower Input(kW)2431.639.552.757.46874.981.790.8105.5111.4120.7134154.4171.3
Current(A)40.453.266.488.696.5114.3125.9137.3152.7177.3187.2202.8225.3259.6288
Capaty Regul0-33-66-100%
(33% for start)
0-25-50-75-100%
(25% for start)
RefrigerantTypeR22/R407C
ControlThermal Expension Valve
CondenserTypeHigh Efficiency Shell&Tube Heat Exchanger
Water Pipe Connection(mm)DN65DN80DN100DN125DN150
Water Flow
(m³/h)
222938505569758189106112123138161177
P drop(KPa)383839434446464749495151555761
EvaporatorTypeHigh Efficiency Shell&Tube Heat Exchanger
Water Pipe Connection(mm)DN65DN80DN100DN125DN150
Water Flow
(m³/h)
172330404455606572859098111129142
P drop(KPa)373739424245454648484949525558
Overall SizeLength mm240024002600285030003000305031003100310032003200330033003650
Width mm90090090090011001100110011001100110011001100110011001100
Hight mm135013501430143015401780180018301900200020002100205020502100
NoisedB(A)646566666868697072727372737274
WeightKG85010501270143016701740183023502400260027802870320034003600
Run WeightKG90011001400156018901890205025102620283030003090343037004000
Specifications of LTLS Series Water Cooled Screw Comperssors Chillers(Double Compressors Model)
MODEL LTLS-60WD80WD100WD120WD140WD160WD180WD200WD220WD240WD260WD280WD320WD360WD400WD
Cooling
Capacity
KW200273352467.2512638.4698.6756.2832.499010461144128814891647
103kcal/hr172235303402440495549575601626650683716784851
Heat RecoveryKW74101129172188232255276304360381416467543597
104kcal/hr6.48.711.114.816.22021.923.726.23132.735.740.146.751.3
CompressorPower Input(kW)4863.279105.4114.8136149.8163.4181.6211222.8241.4268308.8342.6
Current(A)80.8106.4133177.2193228.6251.8274.6305.4354.6374.4405.6450.6519.2576
Capaty Regul0-16.5…..100%
(16.5% for start)
0-12.5…...100%
(12.5% for start)
RefrigerantTypeR22/R407C
ControlThermal Expension Valve
CondenserTypeHigh Efficiency Shell&Tube Heat Exchanger
Water Pipe Connection(mm)DN80DN100DN65
×2
DN80
×2
DN100×2DN125×2DN150
×2
Water Flow
(m³/h)
435976100110137150163179213225246277322354
P drop(KPa)454546495555585565667071747576
EvaporatorTypeHigh Efficiency Shell&Tube Heat Exchanger
Water Pipe Connection(mm)DN80DN100DN125DN150DN200
Water Flow
(m³/h)
3447618088110120130143170180197222258283
P drop(KPa)525253545555605568697273727373
Overall SizeLength mm337033703470347035003780378037803780385038503850389038903890
Width mm9009001100110013001300130013001300130013001300150015001500
Hight mm144014401530158517651950197019801980200020002000227022702270
NoisedB(A)676869697171717172737575757576
WeightKG165018502300240030003500400042504500530058006000630070007500
Run WeightKG190021502550275035504000445047504950605063006500680075508050

Remark:1.Colling Condition: Chilled water in/out 12/7°C; Cooling water in/out 30/35°C;

2.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;

3.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;

4.There may be Changes for improvement without notice, confirm always before your order.

Water Cooled Chiller Introduction:

Features of Water Cooled Chiller:

1.30 sizes available ranging from 100kW to 1600kW cooling capacity;

2.Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.

3.Semi- hermetic screw compress or for all models. Each compressor is equipped with a crankcase heater and a thermal overload cut-out, the screw compress or is also complete with a built-in electronic protection with temperature sensor located directly in the motor win ding and on discharge line.

4.The refrigerant circuit is complete with sight glass, filter drier, high and low pressure gauges, solenoid valve, direct expansion valve, high and low pressure switch.

5.Shell and tube dry expansion type condense r, factory insulated with flexible close cell material.

6.The electric panel consists of compressor breaker, compressor contactor, phase sequence relay, control circuit breaker, microprocessor control with function display.

7.LCD display, touch screen control panel as standard.

8.Automatic operation dramatically reducing maintenance cost thanks t o reliable microprocessor system.

9.For the u nits with semi- hermetic screw compressor, an infinitely variable capacity control system that is capable of exactly matching the demand requirement of the system is to be supplied. This system is to provide precise and stable control of supply water temperature over the complete range of operating conditions.

System Control of Water Cooled Chiller

1.Imaged system operation chart, showing the temperature of water in/out, the energy level of compressor run, on/off button, run time, alarm etc. And the remote turn on/off function is available. PC remote control is optional.

2.Notice for maintenance is indicated according to the accumulated run time of the compressor.It is convenience to maintenance.

3.The control system will automatically balance the run time for each compressor for mult-compressor unit.

Safety Protections of Water Cooled Chiller

1.Discharge check value:it prevents the discharged gas from going back after the compressor stops.

2.Phase lack protection:It protects the compressor for over high voltage, voltage dificiency, and phase lack.

3.Direction protection:It protects the compressor from damage resulted from Counter direction run.

4.Oil heater: It heats the oil before the unit start, keep the good lubrication for the unit before it runs.

5.Overheat protection inside the motor of the compressor: It protects the compressor from burning down for too high coil temperature for overload, or abnormal run condition.

6.High&low pressure protection: It protects the compressor and system against extreme run condition and trouble.

7.Freezing protection: It protects the unit form too low temperature of the water out, freezing may occerat some place, resulting in freezing breaking of the evaporator.

8.Water flow protect: It protects the unit from run without water flow.

9.High temperature of chilled water protection: It works to protect the compressor in case that the load is too large,the temperature of chilled water is too high. It may result in compressor failure without this protect in the case.

Water Cooled Chiller in Warehouses:

Water Cooled Chiller Exports:

LTLS Series Central Air Conditioning Cooling Water Cooled Chiller 100KW-3500KW
Packaging Detail:Wooden Pallets or Cases, Export Standard Packing for Water Cooled Chiller products
Delivery Detail:15days for Water Cooled Chiller

Related Product for LTLS Series Central Air Conditioning Cooling Water Cooled Chiller 100KW-3500KW