HWFS Flooded Water Cooled Chiller

Flooded Water Cooled Chiller, 1)flooded type, 2)R22:368-3035kw R134a:363-1956kw, 3)compressor:1/2/3 system:single/double/three - details see: https://www.machineto.com/hwfs-flooded-water-cooled-chiller-10223078
Type:Chiller,flooded typePlace of Origin:Jiangsu China (Mainland)Brand Name:HammerModel Number:HWFS
Operating Voltage:380/400 VACMounting:Floor StandingCertification:Othercompressor brand name:Bitze or Danfoss
function:coolingcooling capacity(R22):368-3035kwcooling capacity(R134a):363-1956kwcompressor:1/2/3
system:single/double/threeevaporator:flooded typeoil seperator:high efficiencyvalve:electronic expansion valve
HWFS Flooded Water Cooled Chiller
contact supplier for HWFS Flooded Water Cooled Chiller


HWFS Flooded Water Cooled Chiller

Flooded Water Cooled Chiller

We are manufacturer producing fan coil unit(fan coils)/air handling unit(ahu)/chiller

1)R22:368-3035kw R134a:363-1956kw
2)compressor:1/2/3 system:single/double/three Fushen compressor

3)evaporator: flooded type

4) separator :high efficiency separator for chiller

5)valve: electronic expansion valve

6)Siemens PLC for standard chiller unit

5)Chiller Compressor:
Double screw compressor( modified according to our design requirement
1Enlarge outlet size,reduce pressure drop,increase efficiency
2Modify capacity ratio different capacity ratio will be choosen according to different working conditioning
3enlarge rotor discharge outlet volume to increase the efficience
4high quality oil separator design
5check valve optimization design ,pressure drop less than0.02kg/c
Adopted in single compressor 30RT300RT,which is adopted in air conditioner, industry etc
6)Chiller Floodedtype evaporator
working theoryadopting big vessel boiling heat transfer theory, chilled tube is totally immersed in liquid refrigerant , the heat of the water inside the tube will be removed by the refrigerant through heat transfer to make it cool
1.Refrigerant is under boiling situation, water flow is in turbulenc which increase heat transfer efficiency. Superheat of outlet referigerant is around 2~3 , water flows into the cooper tube which is easily cleaned
2. Comparing with falling film exchanger , the constructure is more simple and the heat transfer efficiency is close. Comparing with dry type evaporator, the heat transer efficiency is high.
7)ChillerOil Separator
Self developped high efficient oil separatorto ensure 3ppm return which has been adopted in Hefei General constitute and fushen test equipment
8)ChillerElectronice expansion valvesuction gas over heat control
Gas suction overheat control system is combined by electronic expansion valve, pressure sensor, temperature sensor and controller. P1 of the evaporator outlet is transferred to controller through pressure sensor and overheat is transferred to controller through temperature sensor,after controller handling the signal, it will output the instruction to stepping motor of the electronic expansion valve, then the valve will be opened to the position needed to guarantte the liquid requirment of the evaporator. No matter under any situation like standard ,varialbe working condition or full load,the high COP will be achieved
9)chillerInjection Pump
a)Compact design and simple constructure
b)Efficiency above90
c)Oil return effect achieved with less power consumption
d)No moving parts ensures reliable performance
e)Comparing with other factories, oil return is 15% higher
10)ChillerPLC controller
Compressor coil overheat temp protect and overload protect
Engine oil preheat time on/off
Water flow swtich interlock
Chilled water supply overlow temp protect
Gas discharge over high temp protect
Power failure memory
Frequently on/off protect
Abnormal voltage protect
Oil level over low protect
High/low pressure protect
Auto anti freezing monitor after duty off and seamless exchange with normal condition
Compressor capacity regulating on chilled water temperature basis
On/off according to load
With remote control RS-485RS232 standard interface
Doube compressor working in turn
Running time limitation
running time accumulation
Time on/off
self diagnostic
alarm
Set point can be modifed
Running with LED
Gas discharge temp
Ambient temperature, outlet/inlet water temp
Chiller function
1. Multiple function
can be used for air conditioning, ice maker n and supplying hot water for live to increase the usage
2. High outlet water temp
2 types heat recovery standard R22,
Max. water suppl temp 55the other type is high water supply temp R134a ,high efficiency and max water supply temp 65
4. Self produced evaporator and condensor .
5. specialized design flooded water chiller compressor
6.high efficient oil separator which no needs complicated oil pump system and changeable oil filter mounted inside .
7. humanization touch screen
HWFS Flooded Water Cooled Chiller
Packaging Detail:chiller will be packd with plastic cover or wood case
Delivery Detail:within 30 days after order confirmed

Related Product for HWFS Flooded Water Cooled Chiller