high quality Glass Lined Reactor with Motor, Seal and Agitator
Condition:New | Automatic Grade:Semi-Automatic | Type:Tank Reactor,flanged or monoblock type (open or closed type) | Place of Origin:Shandong China (Mainland) |
Brand Name:zbdwj | Model Number:50L to 30000L | Voltage:380V | Power(W):1.1-30KW |
Dimension(L*W*H):standard or as per requirements | Weight:400-20700 | Capacity:50-30000Liter | Jacketed:with heating/cooling jacket |
Heating mode:steam or electric | Design temperature:200 degree C. | Design pressure:0.6Mpa | Glass layer thickness:0.8-2.0mm |
Glass color:blue | Anti corrosion:resist to acid & alkali | Design Life:6 years |
Glass lined equipment is an ideal material for anti-corrosion and its surface is very easy to polish and no contamintion to mediums. It's widely used in Petrochemnicals, light industry, pharmaceuticals, pesticide, foodstuff, dyes, scientific research etc.
1. Capacity of Glass lined reactor with motor :50 to 30000Liter
2. Structure: Open type (k-type) or closed type( F-type)
3. Material: Vessel: mild steel with glass layer inside surface; Jacket: Mild steel.
4. Design pressure: Vessel ≤0.2Mpa; ≤0.3Mpa; 0.4-0.6Mpa; 1.0Mpa; Jacket pressure: 0.60Mpa
5. Accessories:
One complete set of glass lined reactor generally with motor with Reducer, Seal (optional: Stuffing box;.Single Mechanical seal; Double mechanical seal ), Agitator, Thermometer pocket, bottom discharge Valve
6. Properties and Advantages:
1) Corrosion resistance: organic or inorganic acid, organic solvent and weak alkaline corrosion (not including hydrofluoric acid, containing fluorine medium, phosphoricacid, and alkali concentration greater -than 30% and temperature greater-than or equal 180 Degree Cent.)
2) Pressure resistance: a) Packing box: vessel: less- than or equal 0.2MPa; Jacket:0.6MPa b) Single Mechanical seal: vessel: equal or less than 0.30Mpa Jacket:0.6MPa c) Double mechanical seal: vessel: 0.4 to 0.6Mpa, Jacket:0.6MPa
3) Operation temperature: 0 to 200 Degrees Cent.
4) Glass layer thickness: 0.8 - 2.0mm
5) Cool shock: 110 Degrees Cent.;Thermo-shock: 120 Degrees Cent.
Note:
1. temperature should be slowly changed while heating or cooling glass lined reactor avoid damaging glass layer.
2. Glass lined reactor with motor can not be used in hydrofluoric acid, medium containing fluorine, phosphoricacid , and alkali concentration greater -than 30% and temperature greater-than or equal 180 Degree Cent.
Packaging Detail:Non-packing, steel pallet, or wooden case etc., suitable for inland or marine transportation. |
Delivery Detail:45working days |