FRP square cross flow cooling tower
Condition:New | Cooling Type:Cross Flow | Material:FRP | Place of Origin:Shandong China (Mainland) |
Brand Name:GRAD | Model Number:BHD | Voltage:380v | Certification:ISO9001/ISO14001/ISO18001 |
Warranty:one year | After-sales Service Provided:Engineers available to service machinery overseas |
FRP square cross flow cooling tower
I .Features
1.All parts and materials are rigidly checked and tested to make sure their service life and operation.
2. Unique improved mechanized technology reduces the dead weight of the tower, making the BHD series endowed with advantages of small in size, light in weight, high efficient, long service life and stable operation.
3. Frequency inverter can automatically regulate the fan speed along with the change of water temperature,which can save energy, lower noise and operation cost.
FRP cross flow cooling tower sample
The delivery of cooling tower
The project in Burma
The accessaries of BHD cooling tower
II .Main parts
1. Motor
Totally enclosed motor has the characteristic of high-efficient, low noise, long service life and high reliability.
2.Belt and speed reducer
The belt is imported V shaped belt. The speed reducer cabinet is totally enclosed, it is proved to have stable operation, low noise and fine corrosion resistance and water-proof performance.
3. Fan
Electrochemical protection surface has gone through balance test. It has the characteristic of large air volume, high efficiency, low noise and corrosion resistance ability.
4. Air duct
It is made of high quality FRP compound material.The smooth surface reduce the air resistance effectively.
5. Panels and water collecting tank
Both are made of high quality FRP compound material. The surface is imported UV resistance gel coat, durable and strong.
6.Filling
PVC material filling is hydrophilic and corrosion resistant. It also has a larger heat rejection area, lower air resistance, and higher cooling capacity.
7. Frame
It is made of high-strength steel. The surface has gone through preservative treatment, corrosion resistance, light and easy to assemble.
III
BHD series cross flow cooling tower specification and technical data
Model | Water flow (m3/h) | Cooling capacity (x1000kcal/h) | Motor power (kw) | Fan diameter (mm) |
BHD-100 | 100 | 500 | 3 | 1768 |
BHD-125 | 125 | 625 | 3 | 1768 |
BHD-150 | 150 | 750 | 3 | 2168 |
BHD-175 | 175 | 875 | 4 | 2168 |
BHD-200 | 200 | 1000 | 4 | 2560 |
BHD-225 | 225 | 1125 | 5.5 | 2560 |
BHD-250 | 250 | 1250 | 5.5 | 2954 |
BHD-300 | 300 | 1500 | 7.5 | 2954 |
BHD-330 | 330 | 1650 | 7.5 | 3340 |
BHD-370 | 370 | 1850 | 11 | 3340 |
BHD-400 | 400 | 2000 | 11 | 3744 |
BHD-450 | 450 | 2250 | 15 | 3744 |
BHD-500 | 500 | 2500 | 15 | 4140 |
BHD-600 | 600 | 3000 | 18.5 | 4140 |
BHD-700 | 700 | 3500 | 18.5 | 4540 |
Note:
The cooling capacity is tested under the condition of entering temp 37°C,leaving temp 32°C,wet bulb temp 28°C,atmosphere pressure 99.4kpa.
IV .Technical data needed for choosing model and quotation
You should provide the following technical data for quotation:the entering temp,leaving temp,air flow and wet bulb temp.