Data center cooling system design precision air conditioner

1.Precision air conditioner, 2.Cooling capacity:10~35kw, 3.R22, R407C, R134A, 4.High static pressure duct type - details see: https://www.machineto.com/data-center-cooling-system-design-precision-air-conditioner-10222576
Condition:NewType:Cabinet Air ConditionerPlace of Origin:Shanghai China (Mainland)Brand Name:Shenglin
Model Number:GT- HFM seriesOperating Voltage:380/400 VACMounting:Floor StandingCertification:CE,CE,ISO,RoHS
Air filter:Primary efffect plate type filterCondenser type:Inner grooved copper tube and aluminum finEvaporator type:Inner grooved copper tube and aluminum finCompressor:Totally enclosed scroll type
Application:Cabinet precision air conditionerCooling/Heating:Cooling/HeatingPower Source:ElectricalVoltage (V):220/380
Management:Powerful Network Management   
Data center cooling system design precision air conditioner
contact supplier for Data center cooling system design precision air conditioner


We are a professional heat exchanger, condenser, evaporator and heat pump manufacturer in China.Our products have been exported to Europe, USA, Japan and Middle east etc.

Precision air conditioner

Model Specifications:

GT-HFM series constant temperature and humidity precision air conditioner specification
Model GT-HFM-()3540505560708090
SpecificationTotal cooling capacitykW36.542.149.154.16171.681.493.6
Sensible cooling capacitykW33.838.444.349.855.565.174.785.1
Electric heatingkW1518181824243030
Air volume 2*m3/h1050011500130001550018000205002200025000
Outlet air pressure 2*Pa75757575100100125125
Noise 3*dB(A)5658585858586060
Temperature control range and accuracy°C18~28,±1
Humidity control range and accuracy%45~70,±5
Power3N-380V-50Hz
Input power4*kW3038.239.640.752.356.766.874.8
Indoor unitSupply air fantypelow noise centrifugal type
capacitykW2.23345.57.57.511
Electrode humidifierhumidification volumekg/h1313131515151821
Electric heatingcapacitykW1518181824243030
Evaporator typeInner grooved copper tube and aluminum fin
Air filterprimary efffect plate type filter
DimensionLmm18001800200020002000220022002500
Wmm850850850850850108010801200
Hmm22002200215021502150235023502450
Weightkg5806107107508209009801250
Outdoor unitModel GT-( )*quantity#####WL40*1#####WL55*1WL60*1WL70*1WL40*2WL50*2
compressortypeTotally enclosed scroll type
quantity12222244
condenser typeInner grooved copper tube and aluminum fin
Condensing fantypeLow noise axial type
capacitykW0.750.55*20.55*20.55*20.75*20.75*20.55*40.55*4
DimensionLmm9801880188018801880188018801880
Wmm980980980980980980980980
Hmm12341080108010801234123410801080
Weightkg250320400400450500320*2400*2
Freon5*typeR22(R407C/R410A)
control methodOut balance expansion valve
Collecting pipe6*liquid pipe`s diametermm15.88 (12.7)15.88*2 (12.7*2)15.88*2 (12.7*2)15.88*2 (12.7*2)15.88*2 (12.7*2)15.88*2 (12.7*2)15.88*4 (12.7*4)15.88*4 (12.7*4)
gas pipe`s diametermm34.9 (28.6)22.23*2 (19.05*2)28.6*2 (22.23*2)28.6*2 (22.23*2)28.6*2 (22.23*2)34.9*2 (28.6*2)22.23*4 (19.05*4)28.6*4 (22.23*4)
1.Cooling condition: Indoor dry bulb/wet bulb: 24/17°C;Outdoor dry bulb/wet bulb: 35/24°C;
2.Air volume\static pressure are standard data, it can be designed by client
3.Noise data is measured 3 meters far away from the units
4.The input power means the power consumption under max condtion
5.If freon is R410A or R407C, please noted it in the order
6.The dimension in the brackets is for R410A`s collecting pipe

Precision air conditional pictures:

Production line:

Note:

For further information please contact me