CO2 Detector/Controller
Place of Origin:Zhejiang China (Mainland) | Brand Name:SAIPWELL | Model Number:SPCO2 |
CO2 Detector/Controller
SAIPWELL,AT YOUR SERVICE.
{ SAIPWELL, as a professional manufacturer and supplier, is specialized in developing, producing electric equipments fitting all over the world. Please kindly contact with us freely. High quality,reasonable price,best service is offered to you.}
Intro:
SPCO2 detector/Indicator is used to monitor and alarm CO2
level and room temperature.
Relative humidity detection and display can be as an option. Other options can be provided to users: RS485
communication interface with independent address; one dry contact output to control a ventilation device.
Especial design for schools, kindergartens, office buildings, conference rooms, rest rooms as well as
other public places
Features:
1.Real-time detecting and display CO2 level during 0ppm to 20,000ppm CO2 range; Also detecting room temperature from 5 to 45°C.
2.Optional real-time humidity from 5%RH to 95%RH .
3.NDIR CO2 sensor technology of infrared self diffusion, 15 years lifetime.
4. Self Calibration Algorithm makes it in using without calibration amending.
5.The three measured CO2 ranges for 3-LED indicator lights selectable by end users.
6.LED’s brightness adjustment.
7.Optional 1X dry contact output or one 0~10VDC output to control a ventilation device.
8.Easy preset CO2 level for buzzer alert (optional) .
9.Optional RS485 interface to connect to a PC or another system (optional).
Specifications:
Gas detected | Carbon Dioxide (CO2) |
Sensing element | Non-Dispersive Infrared Detector (NDIR) |
Temperature sensor | NTC |
Humidity sensor | HS series capacitive sensor |
Temperature dependence | 0.2% FS/°C |
Temperature correction | Self compensation |
Power supply | 24VAC/VDC, or 100~240VAC, 60HZ, selectable with the order |
Consumption | 3.5 W max. ; 2.5 W avg. |
Accuracy@25°C(77°F) | ±30ppm + 3% of reading |
Stability | <2% of FS over life of sensor (15 yr typical) |
Calibration interval | ABC Logic Self Calibration Algorithm |
Non linearity | <1% of FS |
Pressure dependence | 0.13% of reading per mm Hg |
Altitude calibration | Programmable from 0-9,900m in 100m increments |
Response Time | <2 minutes for 90% step change |
Signal update | Every 2 seconds |
Warm up time | 2 hours (first time) 2 minutes (operation) |
CO2measuring range | 0~2,000ppm (default) 0~20,000ppm, programmable selection 0~50,000ppmt |
CO2setting & Display resolution | 1ppm |
Temperature measuring/ setting range | 0~50°C(32~122°F)/ 5~45°C(41~113°F) |
Humidity measuring/setting range | 0~99%RH/ 5~95%RH |
Analog output | 0~10VDC linearized output or PID control output, selectable by end users |
Output resolution | 10Bit |
Relay output | One or two dry contact outputs with programmable selection to control CO2, temperature, humidity Rated switching current: 3A(220VAC/30VDC), resistance load |
Communication interface | RS-485, 9600/14400/19200(default)/28800 or 38400bps (programmable selection), 15KV antistatic protection, 3 independent base address, max network node 64 |
Flow rates | Diffusion version 80 ~ 120 cc/min Flow through version 40~50cc/min |
Operation conditions | 0~50°C(32~122°F); 0~95%RH, |
Storage conditions | -10~60°C(14~148°F)/5~90%RH non condensing |
NDIR life | 15 years |
Weight | 360g |
Dimensions | 130mm×90mm×40mm |
Installment standard | 65mm×65mm or 2”×4”wire box |
Interface connections | Maxi. 9 terminals |
Wiring standard | wire section area<1.5mm2 |
Approval Standard | CE-Approval |
Programming and selection | Via internal jumpers and push-buttons on the panel |
Packaging Detail:standing export packing. |
Delivery Detail:30-45days |