Closed circuit counter flow cooling tower
Condition:New | Cooling Type:Counter Flow | Material:Metal | Place of Origin:Shandong China (Mainland) |
Brand Name:Heng An | Model Number:BNX generator cooling tower for sale | Voltage:220V/380V/415V etc | Dimension(L*W*H):As requirement |
Certification:CTI,ISO,BV,CCS,etc | Warranty:12Months | After-sales Service Provided:Overseas service center available | Cooling coil material:stainless steel/Hot-Dip Al-Zn Alloy-Coated Steel Sheet etc |
Water flowing rate:0.001% | Maintenance:with access door and ladder | Structural steel supplier:Bao Steel | Anti-corrosion way:The overall heat invasion zinc |
Nozzle material:ABS | Design Center:National Heat Exchange Center(in Shandong University) |
Closed cooling tower:
1. It can avoid the the fluid being polluted
2.It flow by the coil , will not meet outside air, so it will reduce scaling inside, improving the system effective.
3.It reduces the system energy cost
4.It reduces the system repair cost
5.It assures that the system can run smoothly all of years.
A. Working Principles:
Working fluid(water,oil o other liquid) i flowing inside of the coils,which is enwrapped by spray water on the outside. The heat of water is transferred by coil and become the saturated vapor when meet the water and air. Teh heat is exhausted out of the tower by the tower by the top fan; water is collected back to the bottom tank and circulates continuously. Teh spray water is cooled down via PVC radiation fin in the process of circulation, and flows n the same direction with the fresh wind. The coil mainly takes sensible heat travel style. The most benefit of this style is can avoid scale formation on the outside of th coil. And this will apply especially to dealing with high temperature fluid (e.g. 60°C) or the fluid need big temperature difference (e.g. 60°Cto 35°C).
B.Detailed information:
Part of BHX series Combined-flow Closed Cooling Tower Parameter | ||||||
Type | Total Length | Single cabinet width | Height of the cooling coil | Coil straight length | Coil number | |
unitary | BHX-245 | 1820 | 1740 | 620 | 1520 | 56 |
BHX-280 | 1820 | 1740 | 620 | 1520 | 56 | |
BHX-320 | 1820 | 1740 | 620 | 1520 | 56 | |
single box | BHX-380 | 1820 | 1740 | 1090 | 1520 | 36 |
BHX-430 | 1850 | 1740 | 1090 | 1520 | 36 | |
BHX-475 | 1850 | 1740 | 1320 | 1520 | 36 | |
BHX-495 | 1850 | 1740 | 1320 | 1520 | 36 | |
BHX-550 | 1950 | 1840 | 1090 | 1620 | 56 | |
BHX-595 | 1950 | 1840 | 1090 | 1620 | 56 | |
BHX-670 | 1950 | 1840 | 1320 | 1620 | 56 | |
BHX-700 | 1950 | 1840 | 1320 | 1620 | 56 | |
BHX-735 | 1950 | 1840 | 1320 | 1620 | 56 | |
double box | BHX-900 | 3590 | 1740 | 1090 | 3200 | 36 |
BHX-960 | 3590 | 1740 | 1320 | 3200 | 36 | |
BHX-1050 | 3590 | 1740 | 1320 | 3200 | 36 | |
BHX-1165B | 3790 | 1840 | 1320 | 3400 | 40 | |
BHX-1285B | 3790 | 1840 | 1320 | 3400 | 40 | |
BHX-1335B | 3790 | 1840 | 1320 | 3400 | 40 | |
BHX-1420 | 3790 | 1840 | 1320 | 3400 | 56 |
The above is only a few models. We design cooling tower based on your situation.
C.Products show:
1, cooling the induction furnace of steel plant and jobbing foundries, cooling rolling machine, cooling the quenching tank, cooling the continuous casting.
2,cooling the hydraulic oil, electroplating solution, quenching oil, circulating water production line and other cooling industrial fluid;
3,cooling the water source heat pump system, computer room air conditioning system, auxiliary cooling system and other cooling air conditioning systems .
4,cooling the air compressor water jacket, injection mold, transformers, engine water jacket and other cooling industrial facilities.
5,cooling other equipments, such as power plants, paper mills, food factories.
If any questions ,Pls contact with me
Packaging Detail:Wooden packing, Plywood board packing, 20 feet container, 40 feet container for the cooling tower. |
Delivery Detail:in 30 days after the deposit of the cooling tower |