Central Air Conditioning Air Handling Units
Condition:New | Type:Cabinet Air Conditioner | Place of Origin:Guangdong China (Mainland) | Brand Name:Head-Power |
Model Number:ZK Series | Operating Voltage:380/400 VAC | Mounting:Floor Standing | Certification:ISO9001:2000 ISO14001:2004 |
Functions:cooling/heating | Air flow:3000~200000m3/h | Humidification:5~400kg/h |
Central Air Conditioning Air Handling Units
Features:
1. Hinged access door for central air conditioning air handling units
Inward/outward opening design; outward opening is used in the negative pressure section;
Inward opening is adopted in the positive pressure section, to reduce air leakage and ease daily maintenace.
2. Air dampers for central air conditioning air handling units
Type: the sealed foil multi-vane regulating valve can be arranged as manual or automatic regulating type.
Structure: aluminum alloy or high-strength galvanized steel plate vanes, frame, transmission shaft, transmission gear, sealing strip, sealing block.
Features: gear transmission and vane opening angle are in the linear ratio relation, H=0.035, ideal valve regulation function.
Applications: used for the manual or automaatic regulation of air flow supply, distribution. throttling and bypass.
3. Cabinet accessories for central air conditioning air handling units
Two-layer transparent thermal insulation window, 24V anti-damp, anti-explosion inspection lamp, safety switch for access door, water seal, starting control cabinet, and so on.
4. Fan for central air conditioning air handling units
AMCA certified global brand fans, DIDW type, forward or backward centrifugal fans, subject to trict static and dynamic balance tests, with balance precision no lower than that of ISO1940-G4.0 standard.
Taper-sleeve bearings are used for the fans to reduce the vibrantion caused by the eccentric-lock bearings; the attached SKF or NSK bearings have service life longer than 7500 hours in designed working condition.
Major parts of the fan: impeller, shaft and volute casing have service life no less than 15 years in normal use conditions.
Low runnig noise, high efficiency, mighty structure and stable performance.
Professional CAD software is used for design optimization, can satisfy the air quantity and air pressure requirements for large scope of applications.
5. Motor for central air conditioning air handling units
Air-cooled hermetic three-phase asynchronous motor is used, enjoys protection level IP54.
Grade F insulation and higher reliability and service life.
Energy-saving: optimized motor design boasts higher efficiency and great energy saving effect.
The bearing enjoys service life longer than 75000 hours in designed working condition, and the whole machines is no less than 15 years.
Standard power supply: 380V/3P/50Hz
6. Vibration isolation system for central air conditioning air handling units
Independent suspension up-down vibration isolation system makes fan and motor run quietly, reduce the noise and energy consumption caused by air turbulence.
The closed self-locking damper combines the characteristics of rubber absorber, air damping and spring damping, with efficiency up to 90%.
An integral base holds the fan and the motor, and according to the load distribution of the parts, corresponding dampers are configured to prevent jumping, andti-vibration and resonance, ensure the fan and motor run smoothly and comfortably.
A flexible joint is used for the cabinet and fan connection, avoids vibration transmission, and the flexible joint material conforms to fire prevention requirements.
7. Transmission system for central air conditioning air handling units
Taper-sleeve type pulleys are used, boast precise machining, good static and dynamic balance, and easy disassembly.
Narrow V-belt transmission, enhanced flexibility and contact area; strong layer shifts up, with transmission efficency </=90%; high transmission power, high frequency flexibility, long service life and can withstand higher preload.
Fan and motor are installed on the C-base, can be regulated vertically or horizontally, to increase the parallelism of the twin-shaft and the pulley and have smoothe belt transmission.
8. Heat exchanger for central air conditioning air handling units
Cold water coil, refrigerant gas coil, hot water coil, steam coil, condenser coil and heat recycle coil.
All coils are subject to optimized design with professional CAD software, not only fully meet the requirements fo typical working conditions, but cater for customer's specific working conditions.
Main structure of high-efficiency coil:
1) staggered copper tubes are connected to honeycomb corrugated aluminum fins, not only provide adequate gas side disturbance and high heat transfer efficiency, but reduce gas side resistance.
2) two flanges and mechanical expansion joint make the aluminum fins and copper tube in close contact, reduce thermal resistance.
3) Circuit process and optimized design take into account higher liquid side heat exchange efficiency and lower liquid side resistance.
4) A variety of sheet distance and tube row combinations can meet the need of wide scope of heating.
When corrosion and acid/alkali protection function is required, coated aluminum or copper fins are proposed. In addition to cold water coil, there are refrigerant gas coil, hot water coil, steam coil, condenser coil etc. available.
All coils are subject to 2.5MPa air pressure leak test.
High temperature difference at liquid side: low-flow, high-cycle, large pipe row coil design, widely used for ice storage, salt water and ethylene glycol series, suitable for the temperature.
High termperature difference at gas side: hierarchical homogeneous temperature refrigeration, high-flow, high-density, multiple row coil design, widely used for the needs of fresh air cooling, dehumidification and small-flow quick cooling.
Coil pipe inlet and outlet may have tread (standard), flange or clamping slot or other optional interface types.
Standard face velocity</=2.4m/s, the backsides of high wind-speed coils are configured multi-folding trench type water baffle, water flow</=0.31g/kg dry air at air speed 3.5m/s.
9. Drain pan for central air conditioning air handling units
The drain pan designed at the bottom enjoys unique split-level large slope dry structure, can effectively restrain sewage retention and bacteria growth.
The middle water tray is used in the two upper-lower parallel coils, to prevent a great deal of water depositing on the lower coil, and increase the heat transfer efficiency of the two coils.
Drain pan outlet enjoys direct external thread connection, and the external water seal(optional) ensures smooth water drainage without overflow.
Allwater trays are subject to water test and leak test.
10. Heater for central air conditioning air handling units
Can be attached by steam coil, hot water coil, condenser coil, heat recycle coil, secondary air box, fin heating tube, PTC heating tube and so on.
11. Low-temperature dehumidifying wheel for central air conditioning air handling units
A wheel dehumidification equipment with special dry absorbent on the surface is used in connection with the air handler, improves comfort.
At the air handling side, the low-temperature high-humidity gas is adsorbed by the wheel; when the wheel turns to the high-temperature exhaust side, the adsorbed water is drained to the outside, achieving the dehumidification purpose.