Condition:NewPlace of Origin:China (Mainland)Brand Name:HUAYUNModel Number:BK-100VA
Voltage:220V/380VPower(W):100Certification:CE, ISO9001-2000Warranty:one year
BK(DK) Series isolation transformer
contact supplier for BK(DK) Series isolation transformer


Model: BK-100VA

Frequency characteristics: low frequency
Power supply phase: single phase

Core shape: E type
Cooling type: dry

Winding type: double winding
Moistureproof way: open

Cooling method: natural cooling type
Voltage ratio: 380/380 (V)

Efficiency (η): 90%
Rated power: 0.1 (KVA)

BK SERIES MACHINE TOOLS CONTROL TRANSFORMER

MODEL

OUTLINE SIZE

(mm)

INSTALLATION SIZE (mm)

MOUNTING HOLES (mm)

BmaxDmaxEmaxAC
BK-5076768361+/-0.454+/-35X12
BK-100849210070+/-0.460+/-2.56X12
BK-1509610511080+/-0.462+/-2.56X12
BK-25010512012588+/-0.473+/-39X11.5
BK-30011512512595+/-0.476+/-39X11.5
BK-400120130130100+/-0.480+/-39X11.5
BK-500134144150100+/-0.486+/-39X11.5
BK-700150150158125+/-0.4100+/-39X11.5
BK-1000150153160125+/-0.4110+/-3.59X11.5
BK-1500160240137134+/-0.4116+/-3.59X11.5
BK-2000189270145158+/-0.4122+/-3.59X11.5
SPECIFICATION: SUPPLY FROM 25VA TO 50KVA.

USE:

BK (DK) series transformer is applicable to 50 ~ 60Hz voltage to 500V circuit, usually used

as a machine tools, mechanical equipment, power transmission and distribution system

Equipment electrical control or local lighting and lamp power use.

FEATURES:

According to the structure: Shell

According to installation mode: vertical

+ Environment

1. ambient air temperature -50 °C to +40 °C, the highest monthly average temperature not

more than +30 °C

2. the installation site elevation not exceeding 1000m;

3. air relative humidity in the ambient air temperature is +40 °C ,not more than 50%,

the relative humidity in the lower temperature can have a higher maximum humidity,

The average maximum humidity in wet months was 90%, and the monthly mean

minimum temperature was +25 °C, and considering the temperature on the surface

of the product of the condensation

+ Input voltage: 220V, 380V.

+ Output voltage: 6.3V, 12V, 24V, 36V

Input and output voltage can be customized according to the client's requirements.