Bio Safety Cabinet (BSC) ClassII A2

Bio Safety Cabinet (BSC) ClassII A2 - details see: https://www.machineto.com/bio-safety-cabinet-bsc-classii-a2-10207362
Place of Origin:TaiwanBrand Name:ACDTAfter-sales Service Provided:Engineers available to service machinery overseas 
Bio Safety Cabinet (BSC) ClassII A2
contact supplier for Bio Safety Cabinet (BSC) ClassII A2


Bio Safety Cabinet (BSC) ClassII A2
Description
  • This is a completely closed cabinet, isolate operating personnel or objects to avoid damage by harmful substances, protective role.
  • It is often used in high-polluting, high toxicity, high hazard job.
  • Exposure to toxic chemical biology, food testing, pharmaceutical and health hazardous industries ideal for devices.
  • Customized size and specification are available to meet customer's requirements

Features

Selection of a biological safety cabinet (BSC)

BSC category

Laboratory type

Type of protection

Class I

Groups 1–3, microorganisms in Risk;
Slightly volatile, radionuclide/chemical protection

Operator, environment

Class Ⅱ A1

Groups 1–3, microorganisms in Risk

Operator, environment, product

Class Ⅱ A2

Groups 1–3, microorganisms in Risk

Operator, environment, product

Class Ⅱ B1

Groups 1–3, microorganisms in Risk;
Slightly volatile radionuclide/chemical protection

Operator, environment, product

Class Ⅱ B2

Groups 1–3, microorganisms in Risk;
Minute amounts volatile, radionuclide/chemical protection

Operator, environment, product

Class III

Groups 1–3, microorganisms in Risk;
Volatile, radionuclide/chemical protection

Operator, environment, product

The categories of Bio Safety Cabinet are defined and classified according to the National Sanitation Foundation Standard, NSF/ANSI 49.

- The Class I BSC is designed primarily for the protection of operating personnel

BSC grades

Inlet air velocity

% of air flow

Exhaust system

Applications

m/s

internal
re-circulated
Exhausted



Class I



0.38

0100External
(hard duct)
It is used for laboratories which are work with nonvolatile, radionuclide/chemical protection, microorganisms in Risk.

- The Class II BSC is designed not only to provide personnel protection but also to protect work surface materials from being contaminated by the room air which is drawn into the cabinet. And it is used for protecting the laboratory environment as well. It is acceptable for working with medium level risk tests. And according to the National Sanitation Foundation Standard, NSF/ANSI 49(2002), it can be defined and classified as 4 types. Their features are compared as below.

BSC grades

Inlet air velocity

% of air flow

Exhaust system

Applications

m/s

internal
re-circulated
Exhausted

Class II A1

0.38

7030

Internal or external
(Exhaust hood)

It is used for laboratories which are work with nonvolatile, radionuclide/chemical protection, microorganisms in Risk.


Class II A2

0.5

7030

Class II B1

0.5

3070

External
(Hard duct)

It is used for laboratories which are work with lightly volatile, radionuclide/chemical protection, microorganisms in Risk.


Class II B2

0.5

0100

- Class III biological safety cabinets are suitable for work in Bio-safety Level 3 and 4 laboratories and provide the protection for the highest hazardous level of the Risk Group 3, Risk Group 4, or above. It virtually is a sealed gas tight cabinet. Moreover, its supply air is HEPA- filtered and exhaust air passes through two HEPA filters which keep the cabinet interior under negative pressure consequently. The only way of accessing to the work surface for operation is by means of heavy duty rubber gloves, which are attached to ports in the cabinet virtually.

BSC grade

Inlet air velocity

% of air flow

Exhaust system

Applications

m/s

internal
re-circulated
Exhausted
Class III

N/A

0100Exhaust air should pass through two filters.It is used for laboratories which are work with lightly volatile, toxic, radionuclide protection, microorganisms in Risk.

Bio Safety Cabinet (BSC) ClassII A2
Packaging Detail:by order
Delivery Detail:by order

Related Product for Bio Safety Cabinet (BSC) ClassII A2