Air cooled water chiller and heat pump R22
Type:Air-Cooled | Place of Origin:Shandong China (Mainland) | Brand Name:Bright | Certification:ISO |
Air cooled water chiller and heat pump, R22
Carel controller, famous compressor
Cooling: 8.1-49.5 KW
Heating: 9.3-54.2 KW
FEATURES:
STRUCTURE
Panels and base frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
HERMETIC COMPRESSORS
Single phase (mod.08÷12.5) compressors, 3-phase scroll compressor (mod.16÷50), with thermal overload cut-out and crankcase heater mounted on rubber vibration isolators.
Models 08÷12.5 are available also with 3-phase scroll compressor.
AXIAL FANS
External rotor type axial fans, equipped with single phase direct drive motors, low noise 6 poles, protection level IP54, provided with a protective outlet grille.
EVAPORATOR
High efficiency tube in tube heat exchanger, factory insulated with flexible close cell material.
CONDENSER
Coils are consisting of seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins, protected with flexible plastic grill.
REFRIGERANT CIRCUIT
Copper tube connection with charge valve, filter drier (smaller size), gas-liquid separator, thermostatic expansion valve (expansion capillary tubes for smaller size), low pressure switch with automatic reset, high pressure switch with manual reset.
The heat pump unit is completed also with 4-way valve, liquid receiver and one way valve.
HYDRONIC CIRCUIT
Built with air vent valve, water drain connection, water circuit safety valve, water pump (For smaller size than 30 model), expansion vessel, male-threaded hydraulic connectors and without water storage tank..
ELECTRIC PANEL
consists of:
Compressor contactor;
Water pump contactor;
Compressor protection breaker;
Water pump protection breaker
Fan motor protection breaker;
Control circuit protection breaker;
Phase sequence relay (only for 3-phase power supplied units);
Fan speed regulator (Optional);
Programmable microprocessor controller;
Heat recovery functions (Optional)
APPLICATION:
Suitable for installing in outspace such as roof, floor and porch, left off the boiler room and the special room, decreased the investment of building project. And without cooling water system such as cooling tower and cooling pump, easy to install and maintain. Applicable to hotels, villas, hospitals, cinemas, stadiums, recreations, office blocks, factories and so on.
This is bill here, thanks for your time. If any questions, please feel free to contact me at any time!
Tel: +86-15953799870
Packaging Detail:Plywood cases |
Delivery Detail:4-6 weeks after receive your deposit |