8kw-120kw,Durable Energy Saving and Environmental friendly Scroll Compressor Air Cooled Chiller for Air Conditioning
Type:Chiller | Place of Origin:Shandong China (Mainland) | Brand Name:LUTE OR OEM | Model Number:LTWF |
Mounting:Floor Standing | Certification:CE | Certificate::CE,CRAA, UL | Type::HVAC Systems |
Cooling Capacity:4.7KW-61.6KW; 8KW-120KW | Compressor:Scroll Compressor | Control System:Thermal expansion valve | Power Supply:3P/380V/50HZ, etc |
Evaporator:High efficient tube in tube heat exchanger | Condenser:With seamless copper tubes | Applicaiton:For building offices, refrigeration cold rooms, theaters, etc | Advantages:Top quality, nice appearance, compact structure, etc |
Scroll Type Air to Water Chiller
Two Kinds of Models:Air Cooled Water Chiller/Air to Water Chiller
1. Cooling Condition: Chilled Water In/Out 12°C/7°C;Ambient 35°C
Models: LTWF03AS-40AD
Cooling Capacity: 8KW-120KW
2.Cooling Condition: Chilled Glycol in/out -1/-5°C; Ambient 35°C
Models: LTWF03ASL-40ADL
Cooling Capacity: 4.7KW-61.6KW
Products Advantages:
1. With scroll, or recipocating compressor of high quality, high efficient heat exchangers, excellent system design, by excllent process, the chillers is of suffient capacity and efficiency.
2. The chillers will work stably for long time period as they are produced by excllent process, composed of reliable control components.
3. Complete safety protection:
a.High&low pressure protection, pressure safety value protection;
b.Overload protection to the compressor;
c.Power supply protect for phase lack, counter phase, voltage too high and voltage deficient;
d.Water system protection for freezing breaking, water lack etc.
Designed Features:
Ready to work only after connected to chilled water system;
1. A stainless steel water vessel,a low noise pump have been fixed inside the chiller;
2.With energy saving fan of large air flow and low noise;
3. The chillers of capacity below 50KW is movable by wheels with them;
4. The chillers of capacity over 50KW are double refrigeration system design that is good to reduce the frequent start and stop for load change. The chillers can run even 1 system is in trouble.
5. Strict test and inspection has been made before the chillers are delivered.
System Diagram:
Technical Data
Remark:
1.Designed Condition:Chilled Glycol in/out -1/-5°C; ambient 35°C;
2.This series units used in low temperature conditions, 25% ethylene glycol to be used as a refrigerant;
3.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
5.There may be Changes for improvement without notice, confirm always before your order.
Overall Size
Products in the Factory
Product Certificates
Packaging Detail:wooden cases with pallet for safe transportation |
Delivery Detail:according to quantity |