11kv measuring tank

1. Stretch forming tank, no leak, 2. Amorphous metals core, 3. Japanese silicon steel core, 4. electrostatic spray steel for box - details see: https://www.machineto.com/11kv-measuring-tank-10300902
Place of Origin:Zhejiang China (Mainland)Brand Name:SAGHUModel Number:JLSInsulation:oil immersed
Tank:Prevent leakageCopper and copper wire:high-purity oxygen-free coppermeasurement core:Japen import coiled silicon steelProtection class core:Amorphous metal
Outside box:Stainless steel or electrostatic spray steelInput Voltage:6KV,10KVOutput Current:1A,2A,5AOutput Voltage:100V
Output Frequency:50HZ   
11kv measuring tank
contact supplier for 11kv measuring tank


30yearsManufacturing history,

10yearsJapan OEM, to create high-quality!

Description

The combined transformer (another name is metering tank) is one kind of outdoor power measuring device, which is composed of two sets single-phase wholly insulated voltage transformers, forming three-phase V/V wiring, and two current transformers are separately series connected to A and C phase.

The 10kv CT PT combined units is one upgraded product based on old product of same kind, just adding moisture-proof device onto oil tank's cover, which could effectively prevent external humidity from entering into oil, so as to prolong service life of product, while, compared with old product, its advantage contains larger capacity, smaller volume and weight, simplifying installing.

This product is applied to certain outdoor circuit of AC50-60Hz, rated volt being 35kV or lower, to be used for metering of current, voltage and electric energy etc. this product is suitable for rural outdoor transformer substation, miniature transformer station and substation of industrial enterprise etc. Adding active and reactive energy meter onto combined transformer is named as high volt power metering tank.


10kv high voltage ct-pt measuring units combined Instrument transformer

Technical data

  1. Metering tank conforms to given provisions in GB17201-2006 <combined transformer>;
  2. Current transformer conforms to given provisions inGB1208-2006andIEC 660044-1;
  3. Voltage transformer conforms to given provisions inGB1207-2006andIEC 60044-2;
  4. The zinc oxide arrester must be installed at certain position with less-than-one meter distance away from product's installation place, for lightning protection.

JLS-10 Voltage transformer technical data
TypeRated primary voltage(kV)Rated secondary voltage(V)Maximum voltage(kV)Accurate level and output capacity COSφ=0.8(lag)(VA)Maximum output capacity (VA)
0.20.5
JLS-1010100122050640
JLS-10 Current transformer technical data
Rated primary current (A)Rated secondary current(A)Accurate level and output capacity COSφ=0.8(lag)(VA)1S Shorttime thermal currentRated peak withstand current
0.2S
15-100510600I1n150I1n

0kv high voltage power measuring industrial electrical power distribution box outdoor power distribution box

11kv measuring tank
Packaging Detail:plastic bag in side and firmsecure wooden case
Delivery Detail:2 weeks