Transformer Oil recycling machine
Type:Press Filter | Structure:Vacuum | Place of Origin:Chongqing China (Mainland) | Brand Name:SINO-NSH |
Model Number:vfd |
VFD insulating oil recycling system is mainly used to improve the properties of insulation oil. It can remove trace water, gas, particulate matters etc. from the insulating oil effectively and rapidly so as to boost performance of transformers, circuit breakers, mutual inductors, cable and capacitors which has insulation system. VFD series specialize in purifying branded oil, insulating oil of high voltage and super high voltage transformer. Additionally, it is suitable for treating low viscosity lubrication oil.
Description
NSH VFD series utilizes coacervation technology, coalescing technology, separating technology and refined purification technology. To remove free, soluble water, carbon, free and dissolved gases and particulate matters from insulating oil effectively and rapidly.
Item | Unit | VFD-30 | VFD-50 | VFD-100 | VFD-150 | VFD-200 | VFD-300 | ||
Flow Rate | L/H | 1800 | 3000 | 6000 | 9000 | 12000 | 18000 | ||
Vacuum Range | MPa | -0.092~~-0.099 | |||||||
Max Vacuum Range | Pa | ≤ 50 | |||||||
Working Pressure | MPa | ≤ 0.3 | |||||||
Temperature Range | °C | 45-65 | |||||||
Water Content | PPm | ≤ 4 | |||||||
Gas Content | % | ≤ 0.1 | |||||||
Breakdown Voltage | Kv | 75 | |||||||
Power Supply | V | ~50Hz 380V(or as needed) | |||||||
Working Noise | dB | ≤ 72 | ≤ 78 | ||||||
Heating Power | Kw | 30 | 48 | 90 | 120 | 180 | 240 | ||
Total Power | Kw | 33 | 52 | 95 | 126 | 186 | 248 | ||
Inlet(Outlet)Diameter | Mm | DN25 | DN32 | DN40 | DN50 | DN65 | DN65 | ||
Net Weight | Kg | 350 | 480 | 750 | 1100 | 1250 | 1420 | ||
Size | length | Mm | 1500 | 1500 | 1900 | 2100 | 2400 | 2600 | |
width | Mm | 1100 | 1250 | 1400 | 1600 | 1700 | 1800 | ||
height | Mm | 1750 | 1750 | 1800 | 1900 | 1900 | 2000 |
Packaging Detail:wooden case |
Delivery Detail:25 days |