reci laser power supply suit for reci laser tube
Place of Origin:China (Mainland) | Brand Name:RECI | Model Number:DY10 DY13 DY20 | Warranty:12months |
Application:used for laser machine to engraving or cutting on the non-metals | Type:DY10 DY13 DY20 | Suit:suit for RECI laser tube |
Main Features:
1) High output voltage and current: when inputting AC220V and outputting current up to 38MA, the voltage can be up to 25KV.
2) Response time: ≤1Ms from the time that switch Signal is given to the output current up to 90% of the setting current
3) Increase the power of laser: Used with 2000mm laser, the peak of laser power can be up to 130W and the average power is 100W.
4) Dramatically lengthen the life of laser.
5) Easy Control: The start and stop of laser can be easily controlled by TTL level. And there are protection switch to test the external water, ventilation, etc.
6) Easy control of laser power: Both 0-5V analog signal and PWM signal can control the laser power.
7) The power supply possesses open circuit protection: Under the condition of good protective earthing, the power supply can work in open-circuit for a short time, which could avoid the damage of laser power supply because of the bursting of laser tube, thereby enhancing the life of power supply.
8) The power supply can take feedback interface which can be used in closed-loop control and testing the working current of laser.
9) The power supply adds a new function, that is timely scene judging which part is damaged, laser tube or laser power.
10) Application: used for laser machine to cut and engraving on the non-materials etc.
co2 laser power supply.
60w
Input | Input | AC220V or AC110V | |
AC Frequency | 47-440Hz | ||
Cold surge current | ≤60A(AC220V input) | ≤30A(AC110V input) | |
Leak current | ≤0.7mA(AC220V input) | 0.4mA(AC220V input) | |
Output | Max output Voltage | DC 35KV | |
Max Output current | DC 23mA | ||
Efficiency | when≤90%load down | ||
Time no-failure | ≤10000 hours | ||
Response speed | ≤1ms | ||
Control port | TLL electricity level switch control, valid electricity has high/low level choices | ||
Vollage-resisting | Input-Output ,input-machine hull: 1500V 10mA 60s AC output cathode and machine hull connection | ||
Protection | Can be used an opening way in a short time | ||
Usage environment | Work temperature:(-10-40)°C.Relative humidity:≤90% | ||
Cooling Type | The compuisive air cooling | ||
size | L×W×H=210×160×95(mm) |
80w~100w
Input Voltage | Input Voltage | AC220V or AC110V | |
AC Frequency | 47-440Hz | ||
Cold surge current | ≤60A(AC220V input) | ≤60A(AC220V input) | |
Leak current | ≤0.7mA(AC220V input) | ≤0.7mA(AC220V input) | |
Output | Max output Voltage | DC 40KV | |
Max Output current | DC 28mA | ||
Efficiency | when≤92%load down | ||
Time no-failure | ≤10000 hours | ||
Response speed | ≤1ms(the time from output of switch signal to 90%of initial setting current) | ||
Control port | TLL electricity level switch control, valid electricity has high/low level choices | ||
Vollage-resisting | Input-Output ,input-machine hull: 1500V 10mA 60s AC output cathode and machine hull connection | ||
Protection | Can be used an opening way in a short time(request the outer shell be good to connect the ground avoid arcing between anode and machine hull connection in the machine) | ||
Vsage environment | Work temperature:(-10-40)°C.Relative humidity:≤90% | ||
Cooling Type | The compuisive air cooling | ||
size | L×W×H=210×160×95(mm) |
100w-200w
Input Voltage | Input Voltage | AC220V or AC110V | |
AC Frequency | 47-440Hz | ||
Cold surge current | ≤60A(AC220V input) | ≤60A(AC220V input) | |
Leak current | ≤0.7mA(AC220V input) | ≤0.7mA(AC220V input) | |
Output | Max output Voltage | DC50KV | |
Max Output current | DC 38mA | ||
Efficiency | when≤92%load down | ||
Time no-failure | ≤10000 hours | ||
Response speed | ≤1ms(the time from output of switch signal to 90%of initial setting current) | ||
Control port | TLL electricity level switch control, valid electricity has high/low level choices | ||
Vollage-resisting | Input-Output ,input-machine hull: 1500V 10mA 60s AC output cathode and machine hull connection | ||
Protection | Can be used an opening way in a short time(request the outer shell be good to connent the ground avoid arcing between anode and machine hull connection in the machine) | ||
Vsage environment | Work temperature:(-10-40)°C.Relative humidity:≤90% | ||
Cooling Type | The compuisive air cooling | ||
size | L×W×H=350×240×95(mm) |
The photos of laser power supply:
Package:
Packaging Detail:carton or plywood depend on clients |
Delivery Detail:we will send the goods immediately after we saw the money |