HOT! genset control panel DSE702AS-HC
Place of Origin:Fujian China (Mainland) | Brand Name:KANPOR | Model Number:KP-controller | Motor Type:AC Motor |
Operating Voltage:DC8V-35V | Power Consumption:<3W | Alternator Input Frequency:50Hz - 60 Hz | Operating Temperature Range:-25 to 70°C |
Weight:0. 55kg |
The module has the ability to monitor under speed, over speed, charge failure, emergency stop, low oil pressure, high engine temperature, fail to start, fail to stop and loss of the speed sensing signal.
The Model is an Automatic Engine Control Module. The module is used to automatically start and stop the engine, indicating the operational status and fault
Conditions by means of an LCD display and a flashing LED on the front panel.
Main features(genset control panel):
micro-computer control;
automatically activated, the shutdown;
real-time display unit operating status and parameters;
visualization of the police state of graphics and logo;
quick information display unit;
LED and LCD alarm instructions;
common custom settings, can be used for import and domestic models and other.
Control features:
emergency parking control
automatic car plate
start delay control
local manually start / shutdown
remote automatic start / shutdown
start the motor from the automatic control
control of warm-up
warm Control
Cold Control
Parking / Idle Speed Control
Protection:
lubricants to protect lower
charger fail rechargeable
emergency generating units down
generating units of public alarm
generator over-voltage under-voltage over-current protection
high cooling water temperature protection
engine overspeed protection
failure of the engine shutdown
start the engine failure
Display data:
Speed of Generator
Battery Voltage
Oil Pressure of Engine
Water Temperature of Engine
generating unit output frequency of exchange
Operating Time of Generator Set
generating units with AC output voltage
generating units with the exchange of current output
Alarm instructions:
stability in the light of public alarm, indicating the red;
public warning lights flashing red display, said there is fault shutdown.
Allocation method:
controller through the front panel configuration parameters.
Operating Voltage | DC8. 0V to 35. 0V, Continuous Power Supply |
Power Consumption | <3W |
Alternator Input Range 3-Phase 4 Wire 2-Phase 3 Wire Single phase 2 wire | 15V AC - 360 V AC (ph-N) 15V AC - 360 V AC (ph-N) 15V AC - 360 V AC (ph-N) |
Alternator Input Frequency | 50Hz - 60 Hz at rated engine speed |
Magnetic Input Range | +/- 0. 5 V to 70 V Peak |
Magnetic Input Frequency | 10,000 Hz (max) at rated engine speed. |
Start Relay Output | 7 Amp DC at supply voltage. |
Fuel Relay Output | 7 Amp DC at supply voltage. |
Auxiliary Relay Output (1-4) | (1)7 Amp DC at supply voltage,(2)7A 250VAC free voltage contact,(3,4)16A 250VAC free voltage contact. |
Dimensions | 200mm x 144mm x 50mm |
Panel cutout | 184mm x 139mm |
Operating Temperature Range | -25 to +70°C |
Storage Condition | Temperature: (-30 - 80)°C |
C. T. Burden | 2. 5VA |
C. T. Secondary | 5A |
Weight | 0. 55kg |
Please feel free to contact us to get more infomation!
Packaging Detail:Carton Box or according to customer's demand |
Delivery Detail:within 19 days |