High efficiency flooded type evaporator for chiller unit

High heat exchange efficiency, Anti-corrosive design, Seawater application available, CE.ASME approved - details see: https://www.machineto.com/high-efficiency-flooded-type-evaporator-for-chiller-unit-10241363
Condition:NewPlace of Origin:Guangdong China (Mainland)Brand Name:H'StarsModel Number:HE-F
Structure:Tube Heat ExchangerLiquid Flow Rate:90m³/hMaximum Working Pressure:2.5MbaVoltage:380v
Weight:750kgDimension(L*W*H):3M*1M*1MPower(W):700kw heat exchange capacityCertification:CE,ASME
Warranty:1 yearAfter-sales Service Provided:Engineers available to service machinery overseasMaterial:copper and carbon-steelTest:100% sealing teat and pressure test
Pressure:0-2.875MpaHeating Capacity:700KWType:high COP flooded typeRefrigerant:R134a, R22, R407C
COP in the chiller:5.1-5.9Painting:Black, red, green or others  
High efficiency flooded type evaporator for chiller unit
contact supplier for High efficiency flooded type evaporator for chiller unit


H’Stars Shell and tube type heat exchanger,

Flooded type evaporator

Anti-crossion evaporator

Dry type evaporator


Flooded type evaporator: Higher COP than the traditional dry type

Refrigerant flows in the shell; Chilled water flows in the tube

Fit for air cooled chiller ,water cooled chiller, seawater chiller


Chiller Unit with flooded type evaporator COP (5.1-5.8)higher than

common chiller with dry type evaporatorCOP (4.1-4.8)

Shell material:carbon-steel; tube material: copper/anti-corrosion aluminium-copper

Flooded type evaporator pictures




Featuresof Flooded Type Evaporator

1.Enhanced copper tubes. Larger heat exchange area

( Dry type: plain tube)

2.Tubes dips inside refrigerant, higher heat exchange effect

( Dry type: tubes inside the chilled water,)

3. No need superheat, evaporating temp. largely raised.

(Dry type: need superheat, lower evaporating temp.

Condition: chilled water inlet/outlet temp. 12°C/7°C

Dry type: 2°C. evaporating temp

Flooded type: 6°Cevaporating temp

Evaporating temp. rises chiller COP rises.

Common dry type evaporator as below:


Dry type evaporator:refrigeration flows in the tube, chilled water flows in the shell.

COP lower than the flooded type, but cost is lower.

We can offer you both flooded type and dry type.

Factory Test:

Pls consider both innitial equipment investment and annual operation fee to decide which one is suitable to you. Following is performance comparasion:

Chiller with flooded type evaporator:

40STD-F1060WS3

COP: 5.8

Cooling capacity: 1000KW

Power input:172KW

Chilled water:12°Cin /7°Cout

Chilling water:30°Cin /35°Cout

R22

380V/3P/50HZ

(R134A ,R407Calso available)

Chiller unit with common dry type evaporator

40STD-1060WD3

COP:4.8

Cooling capacity: 1000KW

Power input:208KW

Chilled water:12°Cin /7°Cout

Chilling water:30°Cin /35°Cout

R22

380V/3P/50HZ

(R134A ,R407C also available)

Chiller with flooded type evaporator efficiency : 20% higher than that with traditional evaporator.

High efficiency flooded type evaporator for chiller unit
Packaging Detail:wooden pack
Delivery Detail:30 days