Gas Scrubber
Gas scrubber, - Based on customer's requirement, - Design Pressure1230 psig, - Wide range of size, dimension, - ASME - details see: https://www.machineto.com/gas-scrubber-10229343
Place of Origin:Shandong China (Mainland) | Brand Name:HH | Model Number:VS-das9856 | Liquid Flow Rate:Up to 859 T/H |
Maximum Working Pressure:1220 psig | Certification:CCC, CE | Structure:SS Screen |
Gas Scrubber
These specifications cover the design and fabrication of multi-cyclotube
type vertical Scrubber to be supplied under these specification and to be
used for the removal of liquid and solid particles from the high pressure
natural gas stream. The Scrubbers will be installed at delivery point of
Gas Field and d/s 12" diameter transmission pipeline for custody
transfer/check metering station which are designed for operating
pressure of 800-1300 psig. The feed gas to the Scrubber shall be of
pipeline gas quality.
SPECIFICATION FOR CYCLOTUBES TYPE VERTICAL SCRUBBER
(A) 30-55 MMSCFD as specified in
the Schedule of Requirement.
(Annexure-IIA)
(B) 30 MMSCFD as specified in the
Schedule of Requirement.
Part | Component | Function |
1 | Separator | to protect the steam make-up valve from wet steam |
2 | Isolation Valve | to isolate the installation from the steam supply |
3 | Strainer | to protect the control valve from detritus |
4 | Self-acting Control Valve | to regulate the steam flow to the heat exchanger |
5 | Check Valve | to prevent the ingress of air into the condensate system |
6 | Temperature Controller | to sense and control the heater outlet water temperature |
7 - 12 inc. | Separator Steam Trap Set | |
13 | Air Vent | to vent air from the condensate system |
14 | Isolation Valve | to isolate the heat exchanger from the flash vessel |
15 | Strainer | to protect the heater float trap from detritus |
16 | Check Valve | to prevent the pump steam supply trap from backflow |
17 | Isolation Valve | to isolate the steam trap set from the flash vessel |
18 | Ball Float Steam Trap | to drain the heat exchanger of condensate |
19 | Sight Check Valve | to prevent condensate backflow |
20 | Flash Vessel | to separate the flash steam and condensate from the heater |
21 - 24 inc. | Pump Steam Supply Steam Trap Set | |
25 | Isolation Valve | to isolate the pump from the steam supply |
26 | Check Valve | to ensure directional flow through the pump |
27 | Condensate Pump | to pump condensate from the receiver |
28 | Check Valve | to ensure directional flow through the pump |
29 | Isolation Valve | to isolate the pump from the condensate system |
30 | Drain Valve | to drain the pump and condensate riser for maintenance |
Packaging Detail:Non-package, iron or wooden pedestal, suitable for inland or marine transportation |
Delivery Detail:20-30days after the contract come into valid |