FFU
Place of Origin:Guangdong China (Mainland) | Brand Name:Mingchi | Model Number:FJ002 | After-sales Service Provided:Overseas service center available |
Efficiency:H13-H15:Size:1175*575*350mm and others | Function:purifying equipment:Stainless steel or paint cold rolled sheet | low spread of chemical gases.:Low energy consumption, lower operation costs. |
Clean Room FFU
Features:
1.Stainless steel or paint cold rolled sheet fan filter unit.
2.Composed of materials which have low spread of chemical gases.
3.Low energy consumption, lower operation costs.
4.Can achieve high value of total static pressure at the maximum air flow.
5.Easy to install between clean room ceiling frames.
6.Low noise, uniform air velocity system design, uniform air velocity.
7.Using well-known brand fan, no need maintenance.
Notes:Our FFU is a fan filter unit intalled in the suspended ceiling for turbulent and laminar flow clean room. The overall design is flexibe, easy to install on some suitalbe ceiling frames. When the hepa filter adopt knife edge frame, this unit can also be used for sump sealing ceiling frame.It can easily match any suspended ceiling frames according to design specifications to achieve the requirements of the cleanliness levels of 100, 10 and
Easy to install between clean room ceiling frames.
The design of the fan filter unit enable it to be easily installed in the ceiling frames without clamps. In order to change the HEPA filter more easily and quickly, it is recommended to prepare a matching panel to facilitate the replacement of the filter in the clean room.
Composed of materials which have low spread of chemical gases.
To meet certain special industrial requirements,all of the materials for the fan filter unit have passed the test for low spread of chemical gases.
Low energy consumption to lower operation costs
Single or three phases, high efficiency, long service life, A/C motors no need maintenance. And also provide speed controller and electronic rectifier electric motor as options to reduce energy loss and cold load and thus reduce the overall operation costs.
Can achieve high value of total static pressure at the maximum air flow.
Adopt low resistance non-separator HEPA filter and the high total static pressure fan.Can provide 50 to 100Pa static pressure outside the machine at the rated air flow.Can add primary efficiency filter.
FFU Filter Unit Parameters:
Model | 570# | 600# | 1170# | 1200# | ||
Nominal Sizes(mm) | 578×578×300 |
| 1178×578×300 | 1208×608×300 | ||
Filter Sizes(mm) | 570×570×69 | 600×600×69 | 1170×570×69 | 1200×600×69 | ||
Fan | 280# | 315# | 315# | 355# | ||
Air Flow(m3/h) | 600~800 | 700~850 | 1000~1200 | 1000~1300 | ||
Voltage/Current | 220V/0.85A | 220V/1.3A | 220V/1.3A | 220V/1.8A | ||
Speed Control | Air flow can be adjusted by speed governor. | |||||
Filter Particles | 0.1~0.3 micron | |||||
Cabinet Material | Anti-static plastic spraying of cold rolled steel plate/aluminum alloy/ stainless steel | |||||
Noise Value | 49~60 Decibel |
We can produce as per reasonable parameters and requirements from customers.
Packaging Detail:stretch film, export carton, pallet |
Delivery Detail:7~10 days |