Dynamic Temperature Control systems SUNDI-2 series -25 to 200 degree

Width Temperature., Centralized control of many reactors, both of material&jacket can control - details see: https://www.machineto.com/dynamic-temperature-control-systems-sundi-2-series-25-to-200-degree-10300560
Product Type:OtherPlace of Origin:Jiangsu China (Mainland)Brand Name:LNEYAModel Number:SUNDI-2 series
After-sales Service Provided:Overseas third-party support availableProcess control:PID PLCInput&display:7-inch colour touch screen displayEvaporator:KAORI Plate heat exchanger
Communication:RS485Case Material:SUS304Refrigerants:R-404ATemperature:-25°C~200°C
Compressor:Emerson/copeland/bock   
Dynamic Temperature Control systems SUNDI-2 series -25 to 200 degree
contact supplier for Dynamic Temperature Control systems SUNDI-2 series -25 to 200 degree


Model

SUNDI-235W

SUNDI-235

SUNDI-255W

SUNDI-255

SUNDI-270W

SUNDI-270

SUNDI-2A0W

SUNDI-2A0

SUNDI-2A5W

SUNDI-2A5

SUNDI-2A6W

SUNDI-2A6

Oil temp. range

-25°C~200°C

controller

PID PLC

Communication

RS485

Temp. control

Option: process temperature control or jacket oil temperature control

Temp. difference

Set or control the temperature difference between jacket oil and raw material process

Temperature feedback

Jacket oil :PT100

Raw material process:PT100

Temp. accuracy

±1°C±1°C±1°C±1°C±1°C±1°C

Heating power

3.5kW5.5kw7kW10kw15kW25kW

Cooling
power

200°C3.5kW5.5kw7kW10kw15kW25kW
100°C3.5kWW5.5kw7kW10kw15kW25kW
20°C3.5kW5.5kw7kW10kw15kW25kW
-5°C3 kW4.5kw6.6kW8kw12kW19kW
-20°C1.8kW2.8kW3.8kW4.6kW7kW12kW

Circulation pump

Max35L/min
2bar
Max50L/min
2bar
Max50L/min
2bar
Max50L/min
2bar
Max110L/min
2.5bar
Max110L/min
2.5bar

Compressor

CopelandCopelandCopelandCopelandCopelandCopeland

Evaporator

KAORI Plate heat exchanger

Input and display

4-inch \7-inch colour touch screen,temperature graph display

Security protection

Self-diagnosis function;freezer overload protection;high pressure switch,overload relay,thermal protection device,liquid low level protection,high temperature protection and temperature fault protection

Closed
circulation system

The whole system is closed circulation system, low temperature did not
absorb water vapor, high temperature did not produce the oil miss.
although at high temperature, pressure will not go up during the system is operating. at low temperature, the system will supplementary oil.

Refrigerant

R-404A

Connection size

DN20DN20DN20DN20DN-25DN-25

Water cooled type

Cooling water at 20 °C

800L/H

1.5bar~4bar

1200L/H

1.5bar~4bar

2000L/H

1.5bar~4bar

2900L/H

1.5bar~4bar

4000L/H

1.5bar~4bar

6000L/H

1.5bar~4bar

Dimension

water cooled400*600*1050400*600*1050600*700*1050600*700*1050700*700*1050700*800*1500
air cooled550*680*1050620*680*1050550*680*1450650*680*1450750*750*16501100*800*1650

weight

water cooled140kg185kg245kg290kg460kg630kg
air cooled175kg235kg285kg325kg550kg

Power

AC 400V 50HZ

6.5kW(max)

AC 400V 50HZ

12kW(max)

AC 400V 50HZ

23kW(max)

AC 400V 50HZ

36kW(max)

AC 400V 50HZ

52kW(max)

AC 400V 50HZ

80kW(max)

Case material

SUS 304SUS 304SUS 304SUS 304SUS304SUS304

Model

SUNDI-2A38WSUNDI-2A60WSUNDI-2A95WSUNDI-2130WSUNDI-2200WSUNDI-2300W

Oil temp. range

-25°C~200°C

controller

PID PLC

Communication

RS485

Temp. control

Option: process temperature control or jacket oil temperature control

Temp. difference

Set or control the temperature difference between jacket oil and raw material process

Temperature feedback

Jacket oil :PT100Raw material process:PT100

Temp. accuracy

±1°C±1°C±1°C±1°C±1°C±1°C

Heating power

38kW60kW95kW130kW200kW300kw

Cooling
power

200°C38kW60kW95kW130kW200kW300kw
100°C38kW60kW95kW130kW200kW300kw
20°C38kW60kW95kW130kW200kW300kw
-5°C30kW36kW70kW80kW110kW170kw
-20°C16kW20kW32kW43kw61kw90kw

Circulation pump

Max130L/min
2.5bar
Max250L/min
2.5bar
Max250L/min
2.5bar
Max250L/min
2.5bar
Max250L/min
2.5bar
Max400L/min
3bar

Compressor

CopelandCopelandCopelandCopelandCopelandCopeland

Evaporator

KAORI Plate heat exchanger

Input and display

4-inch / 7-inch colour touch screen, temperature graph display

Security protection

Self-diagnosis function; freezer overload protection; high pressure switch, overload
relay, thermal protection device, liquid low level protection, high temperature
protection and temperature fault protection.

Closed
circulation system

The whole system is closed circulation system, low temperature did not absorb water
vapor, high temperature did not produce the oil miss.
although at high temperature, pressure will not go up during the system is operating.
at low temperature, the system will supplementary oil.

Refrigerant

R-404A

Connection size

DN-32DN-40DN-40DN-40DN-40DN-65

Water cooled type

Cooling water at 20 °C

8500L/H
1.5bar~4bar
11000L/H
1.5bar~4bar
18000L/H
1.5bar~4bar
11000L/H
1.5Bar~4Bar
18000L/H
1.5Bar~4Bar
25000L/H
1.5Bar~4Bar

Dimension

water cooled950*1200*15001150*1350*15001500*1300*16501750*1300*17502250*1300*17502250*1450*1750
air cooled1400*950*1750

weight

water cooled900kg1150kg1550kg1380kg1680kg2100kg
air cooled

Power

AC400V 50HZ
122kW(max)
AC400V 50HZ
165kW(max)
AC400V 50HZ
255kW(max)
AC400V50HZ
160kW(max)
AC400V 50HZ
240kW(max)
AC400V 50HZ
350kW(max)

Case material

SUS 304SUS304SUS304SUS304SUS304SUS304

Dynamic Temperature Control systems SUNDI-2 series -25 to 200 degree
Packaging Detail:Standard wooden package
Delivery Detail:with 20-25 working days

Related Product for Dynamic Temperature Control systems SUNDI-2 series -25 to 200 degree