Air Cooled Chiller (LTWF Series Cooling Capacity 5-140KW)

Air Cooled Chiller, Air Cooled Type, no Cooling Tower Needed, 5-140KW Cooling Capacity, Hermetic Scroll or Piston Compressor, CE - details see: https://www.machineto.com/air-cooled-chiller-ltwf-series-cooling-capacity-5-140kw-10243425
Condition:Chilled Water Inlet 12℃/Outlet 7℃Type:Air-CooledPlace of Origin:Shandong China (Mainland)Brand Name:LYTTE, OEM, ODM
Model Number:LTWFCooling Capability(kw):5-140KWVoltage:380-460V, 3PH, 50-60HZCertification:CE,CRAA, ISO
Warranty:1 YearsAfter-sales Service Provided:Engineers available to service machinery overseasCooling Capacity:5-140KWApplication 1:Air Codotiong Cooling Providing Chilled Water
Application 2:Industrial Cooling for ProcessingAvantage:No Cooling Tower Needed, Easy InstallationFeatures:High Efficiency Saving EnergyCompressor:Hermetic Scroll or Semi-hermetic Piston Compressor
Compressor Brand:Danfoss, Copeland, Bitzer etc.Condenser:High Efficiency Fin and Tube Type Heat ExchangerEvaporator:Shell and Tube, Tube in Tube or Plate Heat ExchangerProtection:Multi-protection Methods setting
Air Cooled Chiller (LTWF Series Cooling Capacity 5-140KW)
contact supplier for Air Cooled Chiller (LTWF Series Cooling Capacity 5-140KW)


Air Cooled Chiller (LTWF Series Cooling Capacity 5-140KW)

Air Cooled Chiller Features:

1.With scroll, or reciprocating compressor of high quality, high efficient heat exchangers, excellent system design, by excellent process, the chillers is of suffient capacity and efficiency.

2.The chillers will work stably for long time period as they are produced by excllent process, composed of reliable control components and professional control procedure.

3. Units with V type heat exchanger: panels, frame and base are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.

4.3-phase scroll type compressor, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.

5. External rotor type axial fans, equipped with three phase direct drive motors, low noise 8 poles, protection level IP54, provided with a protective outlet grille.

6. Evaporator built with high efficiency tube in tube type heat exchanger, factory insulated with flexible close cell material.

7.Condenser built with seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins.

8. Refrigerant circuit complete with charge valves, filter drier, sight glass, gas-liquid separator, thermostatic expansion valve high & low pressure switch.

9. Hydraulic circuit built with galvanized pipe, complete with water discharge connection for tube in tube heat exchanger and flange type hydraulic connectors in two directions easy for connections from both sides of the units.

10. Electric panel consist of: compressor contactor, fan motor contactor, compressor protection breaker, fan protection breaker, phase sequence relay and microprocessor with function display (display only for master/packaged unit).

11. Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.

12. Complete safety protection:

a. High&low pressure protection, pressure safety value protection;

b. Overload protection to the compressor;

c. Power supply protect for phase lack, counter phase, voltage too high and voltage deficient;

d. Water system protection for freezing breaking, water lack etc.

Applicable Industries

-Industrial Reaction Kettle Cooling -Central Air Conditioning System -Chemical Industry.

-Plastic Injection Cooling -Pharmaceutical Industry.

Two Kinds of Models: Air Cooled Water Chiller/Air to Water Chiller

1. Design Cooling Condition: Chilled Water In/Out 12°C/7°C;Ambient 35°C

Models: LT03AS-40AD Cooling Capacity: 8KW-120KW

-Hermetic Scroll Compressors

-Tube in Tube Type Heat Exchanger for Evaporator

-V Type Fin Air Cooled Condenser

-Water Pump and Water Tank are an optional to built in the chiller

-Chilled Water Inlet/Outlet Temperature 12°C/7°C,Ambient 35°C

-Mostly Used for Central Air Conditioning Cooling

Remark: 1.Colling Condition: Chilled water in/out 12/7°C;Ambient Temperature 35°C;

2. Suitable chilled water temperature: 7-35°C;

3. Power supply: 3P-380V-50HZ; with voltage allowance±10%, voltage dif between the phase lines±2%;

4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;

5. There may be Changes for improvement without notice, confirm always before your order.

2.Cooling Condition: Chilled Glycol in/out -1/-5°C; ambient 35°C

Models: LT03ASL-40ADL Cooling Capacity: 4.7KW-61.6KW

-Hermetic Scroll Compressors

-Tube in Tube Type Heat Exchanger for Evaporator

-V Type Fin Air Cooled Condenser

-Water Pump and Water Tank are an optional to built in the chiller

-Chilled Glycol Inlet/Outlet Temperature -1°C/-5°C, Ambient 35°C

-Mostly Used for Industrial Processing Cooling

Remark:1.Designed Condition:Chilled Glycol in/out -1/-5°C; ambient 35°C;

2.This series units used in low temperature conditions, 25% ethylene glycol to be used as a refrigerant;

3.Power supply: 3P-380V-50HZ;with voltage allowance±10%,voltage dif between the phase lines±2%;

4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;

5.There may be Changes for improvement without notice, confirm always before your order.

Main Parts:

Compressors and Fan Motors:

Products Stocks:

Finished Products:

Air Cooled Chiller (LTWF Series Cooling Capacity 5-140KW)
Packaging Detail:Wooden Cases
Delivery Detail:15days

Related Product for Air Cooled Chiller (LTWF Series Cooling Capacity 5-140KW)