20KW boiler for villa or house used
1.20KW boiler for villa or house used, 2.Double heat exchanger, 3.High quality valve system, 4.Best water tank - details see: https://www.machineto.com/20kw-boiler-for-villa-or-house-used-10211679
Condition:New | Type:Natural Circulation | Usage:heating and output hot water | Structure:gas tube and water tube |
Pressure:low pressure and high pressure | Style:Vertical | Fuel:gas -electricity | Place of Origin:Guangdong China (Mainland) |
Brand Name:Auron | Model Number:L1PB20-BTA | Output:hot water and steam | Dimension(L*W*H):710x450x220mm |
Weight:35KG | Certification:CE | After-sales Service Provided:Engineers available to service machinery overseas | Pump:WILO & GRUNDFOS pump |
Control board:The toppest quality | Water valve:The toppest quality | Gas valve:The toppest quality | Expansion water tank:Rectangle expansion water tank |
Burner:High efficiency saving energy burner | Heat exchanger:The pure cooper raw materials | Chimney pipe:2 layers stainless stell chimney pipe | Cover:1mm thickness powder caoting cover |
Colour:White |
20KW boiler for villa or house used
1.Main application:
Gas boiler for heating and output hot water of bathing & everyday for
water of life
2.Technology parameter:
Product Model | Unit | L1PB20-BTA | ||
Rated Heat Input | Kw | 20 | ||
Min. Heat Input | Kw | 6 | ||
Rated Heating Heat Output | Kw | 18 | ||
Min. Heating Heat Output | Kw | 5 | ||
Rated Output Hot Water Δt=30K | Kg/min | 9 | ||
Gas Type | NG | |||
Rated Gas Pressure | Pa | 2000 | ||
Heating Systerm Water Pressure Range | Mpa | 0.05~0.3 | ||
Safety Valve Openning Water Pressure | Bar | 3 | ||
Domestic Hot Water Systerm Pressure Range | Mpa | 0.05~0.6 | ||
The Water Cycle Way Of Heating | Built-in Closed Water Tank | |||
Water Temperature Adjustment Range | Heating Water Output | °C | 40~80 | |
Domestic Hot Water Output | °C | 30~60 | ||
Heat Efficiency | % | 88-94% | ||
Max.Power Input | W | 105 | ||
Power Supply | V/Hz | AC220V 50Hz | ||
Pump lift | m | 5 | ||
Expansion tank capacity | L | 6.5 | ||
Insulation Grade | Ⅰ | Ⅰ | ||
Index Of Protection | IPX4D | IPX4D | ||
Exhaust Way | Forced Exhaust | |||
Outside Diameter and Inside Diameter Of Exhaust Smoke Gas | mm | Φ90/Φ60 | ||
Max.Permissible Flue Length | m | 3 | ||
Flue Pipe Length Reduction For Elbow | 90°Elbow 90° | m | 1 | |
45°Elbow 45° | m | 0.5 | ||
Fittings | Central heating fitting | Inch | G3/4 | |
DHW fitting | Inch | G1/2 | ||
Gas fitting | Inch | G3/4 | ||
Reference heating square | m2 | <100 | ||
N.W | Kg | 33 | ||
G.W | Kg | 35 | ||
External Dimensions | mm | 710*450*220 | ||
Packing Size | mm | 850*545*330 | ||
Loading Quantity | 20ft | Pcs | 180 | |
40FT | Pcs | 350 | ||
40HQ | Pcs | 445 |
3.The policy of warranty:
.1 year warranty
.Provide the spare parts for free of charge with some easy
broken
.We can replace it if the quality of product is confirmed cause
of ours responsibility
Packaging Detail:1.5 layers carton box packing2.carton box size is 850X545X330mm3.1pcs per carton box 4.there are 2pcs foams in the carton 5.the foam put the left side and right 6.used 2pcs packing belt 7.front side open when you get it 8.attached the plastic bag protection product from the drop rain |
Delivery Detail:after get deposit,the goods will ready to ship within 45 days |