115V/220V 4Q DC Motor Controller Manufacturer
Place of Origin:Shandong China (Mainland) | Brand Name:KEYA | Model Number:MMT-115/230RT10AL | Motor Type:DC Motor |
Type:Motor Controller | Input voltage range:115/230VAC | Output voltage:0-90VDC/0-110VDC/0-180VDC/0-230VDC | Peak currenct:10A |
Continous current:5A | Control mode:potentiometer/ 0---+/-10V | If F/R function:Yes | Outline size:115*100*80MM |
115V/220V 4Q DC Motor Controller Manufacturer
. Summary
MMT-SCR series DC motor controllers are full-wave positive feedback motor controllers and can control motors in It provides four-quadrant operation, which can realize positive and reverse torque in two speed directions.
.Product Features
1. Applicable to permanent-magnet, separate excitation DC motor
2. Large torque for low-speed start-up.
3. The mechanical characteristics of hardness, static error rate of 1%.
4. A wide speed-regulating range (0 - max).
5. A rapid dynamic response process.adjustable
6. Automatic and smooth transition process during acceleration or deceleration.
7. Current setting and current limiting protection (If the preset current value is exceeded, the driver stops output automatically.)
8. Setting functions of and opposite soft start/soft stop time (adjustable)
9. Self lock-up function.
10. Positive rotation and reverse rotation are selectable.
11. Dual closed loop PI adjustment (Current and Voltage)The closed-loop feedback is selectable.
12. The speed control mode and torque control mode are .
13. The inertial gliding stop and braking stop are selectable.
14. The input voltage and output voltage are selectable.
. Main Parameters
1. AC Input Voltage (VAC±10% 50/60HZ) ----------------------------------------115V/230V
2. AC Frequency (Hz) -------------------------------------------------------------------- 50/60
3. Amarture voltage range 115VAC line (VDC) ---------------------------------- 0- ±9 0
4. Amarture voltage range 230VAC line (VDC) ---------------------------------- 0- ±9 0 /0-±180
5. Excitation voltage at 115VAC line (VDC) -------------------------------------- 100/50
6. Excitation voltage at 230 VAC line (VDC) ------------------------------------- 200/100
7. Maximum bearing capacity (% two minutes) --------------------------------- 150
of indoor temperature () ------------------------------------------------------------------- 0-50
9. Speed range in open loop (ratio) -------------------------------------------------- 501
10. Speed range in closed loop (ratio) ---------------------------------------------- 801
11. Regulation of armature feedback loading (% basic speed) ------------- ±1
12. Regulation of closed loop feedback (% rated speed) --------------------- ±1
13. Adjustment of line of alternating current (% basic speed) -------------- ±0.5
14. Current range (A DC) -----------------------------------------------------------------10/15
15. Forward/reverse speed accelerating scope (s) ----------------------------- 0.1- 15
16. Dead zone range (% basic speed) ---------------------------------------------- 0 -±5
17. Range of maximum speed regulation of potentiometer (% basic speed) ------- 55- 110
18. Compensation range in 110VAC line (VDC @ full load) ------------------------------ 0-20
19. IR compensation range in 220VAC (VDC @ full load) --------------------------------- 40
20. Range of forward CL(FCL) and reverse CL(RCL) (% range setting)---------------- 150
21. Volt range changing with the input voltageVDC--------------------------------------- 0-±10/±15
22. Range of voltage with input (% basic speed-------------------------------------------- ±.
23. Ambient HumidityRelative Humidity≤80RH.Below dew point
.Set optional jumper wire
MMT-SCR has the function of customer optional jumper wire, which must be set before implementing control (see the diagram). Letters in bold are set before shipment.
Table 1 Comparison table between location of jumper wire J2 and motor horsepower
motor current at the location of jumper wire J2 | motor horsepowerP | |
90V DC | 180V DC | |
10.0A* | 1.0 (0.75) | 2.0 1.5 |
7.5 | 3/4 (0.5) | 1.0 |
5.0 | 1/2 (0.37) | 1.0 (0.75) |
2.5 | 1/4 (0.18) | 1/2 (0.35) |
1.7 | 1/8 (0.12) | 1/3 (0.25) |
Note: Additional radiator is needed when current is set as 10.0A.
Table 2Relationship between location of BM and J3 and AC input as well as motor voltage
Input voltage of AC line | BM location | J3 location | Motor voltage |
115V | 115V | A90 | 90V |
230V | 230V | A180 | 180V |
230V | 230V | A90 | 90V |
Table 3 Connection mode of excitation (only for shunt motor)
AC line voltage(VAC) | Motor Voltage(VDC) | (VDC) | Excitation connection |
115 | 90 | 100 | F+ F- |
115 | 90 | 50 | F+ L1 |
230 | 180 | 200 | F+ F- |
230 | 180 | 100 | F+ L1 |
Packaging Detail:carton |
Delivery Detail:2days |